Review Date Reviewer's Name Type of Review Description Status Comments
09/10/2026 Commercial Building Standard APPROVED
09/01/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
09/10/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/01/2026 Commercial Electrical Standard REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0826-01297 (720 N LONGFELLOW AV TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Update the Code Analysis Data section to show compliance with the currently adopted codes. https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Building-Codes
2. Provide missing Electrical Load calculations.
3. Show locations of each smoke alarm, [NFPA 72]. Must be inside each bedroom and in the immediate vicinity outside the bedrooms. Notate that all smoke alarms must be interconnected with a power source from the building wiring and be equipped with battery backup.
09/09/2026 Commercial Mechanical Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0826-01297
ADDRESS/PARCEL: 720 N LONGFELLOW AV TUCSON, AZ 85711

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Due to the proposed change of occupancy, please provide ventilation calculations demonstrating compliance with the minimum outdoor air ventilation requirements for the proposed occupancy. Reference: Section 1008.1, IEBC 2024 & Table 403.3.1.1, IMC 2024.
09/09/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0826-01297
ADDRESS/PARCEL: 720 N LONGFELLOW AV TUCSON, AZ 85711

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Please update all code references to reflect the currently adopted City of Tucson codes and amendments. (2024 IPC, IMC, IBC, IECC, etc)
09/08/2026 Fire New Construction Standard REQUIRES RESUBMIT -Please update your code editions on sheet A1.1 to the COT current adopted codes.
-Your code analysis, sheet A1.1, states no fire sprinklers. Please show in the code analysis that new fire sprinklers will be added.
-Please review your occupancy classification of R4 condition 1. Your descriptions under project scope appear to describe an R4 condition 2.
john.vincent@tucsonaz.gov
5203495581
09/04/2026 Site Engineering Standard REQUIRES RESUBMIT Site Engineering Review

TC-COM-0826-01297
720 N LONGFELLOW AV

Date of Transmittal: 9/4/2026

Description: Conversion of existing residence into an assisted living home. Including accessible ramp and accessible restroom.

City of Tucson Code:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes

Site Engineering comments are as follows:

1. A Floodplain Use (FPU) Permit, TE-FPU-0926-00361, was created on the applicant’s behalf because the project exists within a in COT recognized floodplain associated with the Alvernon Wash.


To re-submit, visit the Tucson Development Center Online at:
https://tdc-online.tucsonaz.gov/#/home

Engineering Associate: Ryan Insalaco
ryan.insalaco@tucsonaz.gov
09/09/2026 Site Zoning Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT:
TC-COM-0826-01297 – Commercial – Conversion of existing residence into an assisted living home
720 N LONGFELLOW AV TUCSON, AZ 85711 (C-2 Zoning)
Certificate of Occupancy Review – 1st Review

TRANSMITTAL DATE:
September 09, 2026

1. COMMENT: Add General Note: Proposed Zoning Use; Residential Use Group – Adult Care Services per Use Specific Standards UDC 4.9.7.J.2.a, 3.a, 4 (The City does not use the term ‘Assisted Living’).

2. COMMENT: Per UDC Table 7.4..4-1, demonstrate where the 4 required vehicular spaces will be located including the dimensions of the parking spaces on the site plan. Refer to UDC 7.4.6 for motor vehicle use are design criteria.

3. COMMENT: Per UDC Table 7.4.8-1, demonstrate where the 2 required short-term and 2 required long-term bicycle parking spaces will be located including the dimensions of the parking spaces on the site plan and floor plan (if applicable). Refer to UDC 7.4.9 for parking design criteria.

4. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

5. COMMENT: Updated certificate of occupancy permit.

6. COMMENT: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home .

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .
09/09/2026 Water - PDSD Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0826-01297
ADDRESS/PARCEL: 720 N LONGFELLOW AV TUCSON, AZ 85711

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Reduced pressure backflow prevention assemblies are required at the water meter for licensed, personal care facilities. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, https://www.tucsonaz.gov/files/sharedassets/public/city-services/tucson-water/water-quality/documents/backflow-ordinance.pdf
08/18/2026 PDSD Application Completeness Express REVIEW COMPLETED