Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0826-01292
Parcel: 117032580

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0826-01292
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/01/2026 Commercial Electrical Standard APPROVED
08/25/2026 Site Zoning Standard APPROVED
09/08/2026 Commercial Plumbing Standard NOT REQUIRED
09/01/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
08/19/2026 Site Engineering Standard NOT REQUIRED
09/08/2026 Water - PDSD Standard NOT REQUIRED
09/10/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/10/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please amend the plans to show that all through-penetrations, membrane penetrations and joints of fire-resistance-rated assemblies are protected with approved firestopping systems. Provide detail drawings on the plans identifying the specific UL-listed (or equivalent) firestopping systems for pipe, conduit, and duct penetrations through rated walls, floors, and ceilings (e.g., putty pads, firestop sealants, collars, or sleeves, as applicable). IBC Sections 714 & 715
Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
09/08/2026 Commercial Mechanical Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0826-01292
ADDRESS/PARCEL: 6 E UNIVERSITY BL TUCSON, AZ 85705

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Please clarify how the fresh air intake shown on the plans will provide fresh air to the space. Indicate whether the fresh air will be provided through the HVAC system or a separate system. Reference: Section 403.3, IMC 2024.
2. Please provide heating and cooling load calculations to justify the heating/cooling capacity of the new 5-ton unit. Reference: Section C403.1.1 and C502.3.3, IECC 2024.
09/09/2026 Fire New Construction Standard REVIEW COMPLETED
08/18/2026 PDSD Application Completeness Express REVIEW COMPLETED