Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0825-01580
Parcel: 13338005E

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0825-01580
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/15/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/15/2025 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0825-01580
ADDRESS/PARCEL: (10380 E BROADWAY BL TUCSON, AZ 85748)
COMMENTS:
1. The floral sink needs to be directly connected to the plumbing system since it’s not one of the fixture types listed in IPC Section 802.1.
a. Food-handling equipment, in other than dwelling units, clear-water waste, humidifiers, dishwashing machines and utensils, pots, pans and dishwashing sinks shall discharge through an indirect waste pipe as specified in Sections 802.1.1 through 802.1.7. Fixtures not required to be indirectly connected by this section and the exception to Section 301.6 shall be directly connected to the plumbing system in accordance with Chapter 7. (2018 IPC 802.1)
09/25/2025 PDSD Application Completeness Express REVIEW COMPLETED