Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0825-01513
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/27/2025 | Commercial Mechanical | APPROVED | |||
| 08/27/2025 | Site Zoning | APPROVED | |||
| 08/27/2025 | Water - PDSD | APPROVED | |||
| 08/28/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/28/2025 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0825-01513 ADDRESS/PARCEL: (310 W ALAMEDA ST TUCSON, AZ 85701) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. In your Cover Sheet/Front Page, please list the special inspections required for this project IBC 107.2.1 For example, Post installed anchors. 2. Please provide a special inspection certificate with Part A, and Part B completed with next submittal. This form is available in https://www.tucsonaz.gov/files/sharedassets/public/city-services/planning-development-services/documents/special_inspection_certificate.pdf Ensure that Part B is sealed/signed/dated by the special inspector in charge. Ensure to use Special Inspectors who are active in the approved list of special inspectors. They are available in the following links: special-inspectors-by-name.pdf (orovalleyaz.gov) https://content.civicplus.com/api/assets/e426f390-7bd6-4c47-9bc1-357282083afd https://www.phoenix.gov/pddsite/Documents/TRT/dsd_trt_pdf_00870.pdf 3. Your Minimum Plumbing Fixture calculation table shows 1 water closet and 2 urinals provided for Men. a. Your Floor Plan shows 2 water closets. b. Please clarify, which is correct. c. Please coordinate and make the necessary corrections. 4. Your Minimum Plumbing Fixture calculation table shows 2 water closets provided for Women. a. Your Floor Plan shows 3 water closet. b. Please clarify, which is correct. c. Please coordinate and make the necessary corrections. 5. Break Room/Game Room a. Counted over 50 chairs/occupants in the Break Room/Game Room. b. Per IBC 1010.1.10 panic hardware shall be required for Group A with an occupant load of 50 or more. i. Please resolve this issue. c. Please reverse door swings of the two doors in the direction of egress travel. d. Door Schedule i. Please revise your table to reflect the panic hardware requirements. ii. Please list any existing door that has panic hardware. 6. Code Plan – Second Floor a. The egress of travel route are shown in diagonal manner. i. Please show the furnitures on the plan. ii. Please correct the travel route in a rectilinear manner and correct the distance traveled for each route. 7. Please resubmit. Should you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 08/15/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0825-01513 (310 W ALAMEDA ST TUCSON, AZ 85701) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Provide complete compliance with the 2018 IECC for the interior lighting, including sensors and lighting controls as required. (typically COMcheck). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/27/2025 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Provide an air gap discharge for the potable clear water waste from the ice machine and the storage-type water heater. Reference: Section 802.1.3, IPC 2018. 2. Indirect waste receptors shall not be installed in concealed spaces. Provide ready access to the waste receptor. Reference: Section 802.4, IPC 2018. |
||
| 08/20/2025 | Fire New Construction | REVIEW COMPLETED | |||
| 08/13/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |