Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.2
Permit Number - TC-COM-0825-01512
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/26/2025 | Commercial Building | APPROVED | |||
| 09/29/2025 | Site Engineering | NOT REQUIRED | |||
| 09/15/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0825-01512 (7671 E TANQUE VERDE RD Unit:BLDG D TUCSON, AZ 85715) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Provide Electrical load calculations which demonstrate that the premises electrical system has load capacity to accommodate the EV charging load (Include the EV charger in the load calculations as a continuous use item). NEC 625.42. >>> The load calculations for the panel ‘MDP-1’ are the exact same as the ‘EV Panelboard’ calculations. Provide the correct load calculations for the ‘MDP-1’ panel. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 09/29/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons PDSD Zoning Review Section PROJECT: TC-COM-0825-01512 7671 E. Tanque Verde Rd. Bldg. D Tucson, AZ 85715 EV Charger In Existing Parking Lot (1st Review) TRANSMITTAL DATE: 9/29/2025 Comment: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. This site is located in the O-3 zone (UDC 4.7.15). 1. Comment: The proposed pedestal mounted EV charging stations cannot be located within the minimum required parking space (8 ½’ x 18’). Either demonstrate the minimum parking space size is met or relocate your pedestals to meet the minimum requirements. A development package may be required depending on the updated pedestal location. 2. Comment: Additional comments may be forthcoming based on responses to zoning comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 09/10/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |