Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.3
Permit Number - TC-COM-0825-01498
Review Name: COMMERCIAL REVIEW - LIMITED v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/30/2025 | Commercial Electrical | APPROVED | |||
| 09/30/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/24/2025 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 2nd Review 9/24/2025 Building/Accessibility 1. THIS COMMENT PARTIALLY REMAINS: The future work proposed for the breakroom should all be shown as accessible. For example, the microwave oven, breakroom sink, and countertop should be shown as per 2009 ICC A117.1-804 Please provide the clear floor space on the plans to show the method of approach, either a parallel Approach or a Forward Approach 2009 IBC 107.2.1/ICC A117.1 NEW COMMENTS FROM SECOND REVIEW 5. Please submit all the sheets listed in the Sheet Index with your next submittal and ensure all sheets have a unique label matching the Sheet Index. For example, 8 of the 10 sheets were submitted and one sheet is missing the title block and sheet label. IBC 107.2.1 |
||
| 09/24/2025 | Commercial Mechanical | REQUIRES RESUBMIT | NEW COMMENTS FROM SECOND REVIEW: 5. Sheet M-1.0: Please amend the plans and the ventilation calculations as follows: A. Mechanical Symbols depicts Two 6-ton Heat Pumps, and the Outdoor Air Calculations show two 5-ton units B. The factors for the ventilation calculations appear to be using some factors for Barber Shop and some from Beauty Salon. C. The Beauty Salon Outdoor/Air/Person factor should be changed from 7.5 to 20 per IMC Table 403.3 D. The resultant Outdoor Air required should be changed from 742 CFM to 1667 CFM C. Additionally, the total required exhaust provided should be revised from 1045 CFM to 1613 CFM |
||
| 09/24/2025 | Commercial Plumbing | REQUIRES RESUBMIT | NEW COMMENTS FROM SECOND REVIEW: 3. Sheet P1.0: Please show the water supply to the future refrigerator on the isometric drawing. IBC 107.2.1 |
||
| 09/10/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |