Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0825-01483
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/29/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Please amend the occupant load calculations using the occupant load factors in the table 2018 IBC Table 1004.5 to arrive at the total occupant load. IBC 1004.1 For example, Business area (Office) is now 150 SF per person, Mercantile is now 60 SF per person and Storage remains 300 SF per person. When this is recalculated the occupant load will likely be below 14 and then a drinking fountain is not required. IBC 2902.6 2. Please amend the plans to show where the nearest public restroom facilities are located within 500ft of the store’s entrance IBC 2902.3.3. If public restrooms are not available within 500t, the source of hot water for the bathroom lavatory in the store shall be shown on the plans, since the plans show an abandoned water heater in the bathroom. IBC 107.2.1 & IPC 419.5 Tempered water for public hand-washing facilities. 3. Please amend the plans to show progress towards making this space 100% accessible IEBC 305.4.2 For example, grab bars could be added in the toilet room. Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 08/28/2025 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0825-01483 2680 E VALENCIA RD Unit: 192 – P-I Smoke Shop (2nd Review) TRANSMITTAL DATE: August 28, 2025 Resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the P-I zone (UDC 4.7.28). Smoke shop is not an allowed use in the zone. 1. Per UDC Table 4.8-5 Retail Trade Land Use Group With Land Use Class/Type: a Smoke Shop is not an allowed use in the P-I Zone. Best case a Board of Adjustment for Variance maybe required but most likely a rezoning will be needed. An option would be to contact PDSD Zoning Administration an attempt to secure a nonconforming letter for this addressed. https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 08/27/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 08/07/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |