Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0824-01701
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/23/2024 | Site Engineering | APPROVED | |||
| 09/24/2024 | Fire New Construction | NOT REQUIRED | |||
| 10/29/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/18/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Please amend plans to provide a list of the year and name of the adopted applicable codes from the adopting ordinance. IBC 107.2.1 2. Please amend plans to provide architectural drawings to show details are that show the drip edge, flashing and intersection detailing of water resistive components, and as otherwise needed. IBC 107.2.4 3. Please amend plans to provide exterior elevations are shown to scale for the structure. IBC 107.2.1 4. Please amend plans to provide finish floor elevations of the existing structure, the sidewalk and the new porch slab. IBC 107.2.1 5. Please amend plans to provide the following information on the structural plans: IBC Section 1603.1 A. Floor and roof dead and live loads. B. Ground snow load, Pg. C. Basic design wind speed, V, miles per hour (mph) (km/hr) and allowable stress design wind speed, Vasd, as determined in accordance with Section 1609.3.1 and wind exposure. D. Seismic design category and site class. E. Flood design data, if located in flood hazard areas established in Section 1612.3. F. Design load-bearing values of soils. G. Rain load data. 6. Please amend plans to indicate the Risk Category per IBC Table 1604.5 7. Provide material specification for the construction material used (e.g. concrete strength, rebar size and grade, lumber species and grade, and etc.). IBC 107.2.7 8. Please amend plans to provide fastening schedule per IBC Table 2304.10.1. 9. Please provide design, details and calculations for Porch structure, that includes vertical and lateral structural analysis, prepared by an Arizona licensed registrant. IBC 107.2.1 For the post-installed anchors, provide the following: A. Detail and specify distance from center of post-installed anchors to edge and sides of foundations on the foundation plan. B. For post-installed anchors, provide calculation per ACI Chapter 17 and dimension the side distance on the detail(s) to accurately reflect the distance used in the calculation. Include overstrength factor for post-installed anchors into existing concrete. C. Special inspection is required per IBC 1704 for expansion anchors, epoxy anchors, and powder-driven pins. Revise the plans to include a special inspection section that list the required special inspection for the project. D. If Special inspections are required, please provide a statement of special inspections for this project, as well as a list of the required special inspections. IBC 107.2.1, IBC 1704, IBC 1705 I. Additionally, provide the City of Tucson Special Inspection Certificate(s) with Parts A and B completed with the next submittal. IBC 107.1 SI form link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 10/29/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Fernando García Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0824-00225 – Commercial Building 1702 S Winmor Av, Tucson, AZ 85713 Building Plan Review (1st Review) TRANSMITTAL DATE: October 29, 2024 This site is located in the R-1 zone (UDC 4.7.8). Religious use is a permitted use in an R-1 zone. 1. (Comment) Per Unified Development Code (UDC) Section 3.3.3.G, a development package is required to be submitted and approved prior to the approval of a commercial building permit for an expansion of use. The requirements for a development package can be accessed at the following link: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Development-Package RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Development package to be submitted and approved prior to approval of the building permit. If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov. |
||
| 09/23/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |