Permit Number: TC-COM-0824-01669
Parcel: 11918029F

Address:
1240 W AJO WY

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0824-01669
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/06/2024 Fire New Construction NOT REQUIRED
09/25/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
09/24/2024 Commercial Structural REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0824-01669
ADDRESS/PARCEL: (1240 W AJO WY TUCSON, AZ 85713)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter.
COMMENTS:
1. Submit an image of the light fixture for light fixture A as well as its specification to include the light source kelvin temperature and the lumens output.
2. Submit the Outdoor Lighting Code
3. Detail 3/D1 - dimension from the handrail to the stair tread nosing is unclear. Ensure that it is between 34” and 38”. Indicate this on the drawing complying to IBC 1014.2
4. Detail 3/D1 – Handrail shall extend horizontal not less than 12 inches beyond the top riser and continue to slope for the depth of one tread beyond the bottom riser per IBC 1014.6
5. Please resubmit.
08/29/2024 PDSD Application Completeness REVIEW COMPLETED