Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0824-01612
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/16/2024 | Water - PDSD | APPROVED | |||
| 09/16/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/05/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 9/4/2024 12:50:00 AM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 8/26/2024 4:35:04 PM 1. Sheet g1.05/ UL 348: UL fire resistant rated wall assemblies typically use proprietary materials as part of the testing process for the listing. Please provide the most recently published complete listed assembly for UL U348. The most recent version of this assembly, as published by UL is dated May 08, 2024. 2. Sheet g1.06/ UL P522: UL fire resistant rated wall assemblies typically use proprietary materials as part of the testing process for the listing. Please provide the most recently published complete listed assembly for UL P522. The most recent version of this assembly, as published by UL is dated June 14, 2024. 3. Sheet g1.08/ UL U305: UL fire resistant rated wall assemblies typically use proprietary materials as part of the testing process for the listing. Please provide the most recently published complete listed assembly for UL U305. The most recent version of this assembly, as published by UL is dated June 14, 2024. 4. Sheet g1.11/ UL L530: UL fire resistant rated wall assemblies typically use proprietary materials as part of the testing process for the listing. Please provide the most recently published complete listed assembly for UL L530. The most recent version of this assembly, as published by UL is dated June 27, 2024. Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 9/3/2024 1:35:34 PM Electrical(E) Reviewer Ron Ross rross@safebuilt.com Denied Reason: Date Completed : 8/23/2024 12:59:24 PM 1. ES1.0 is missing Keynote 6 and has no description for Keynote 7. 2. E1.0 has rooftop Condenser unit on a different panel (panel A) than unit panel B. Same comment about water heaters and the receptacles in Living room. 3. E1.0 why does water heater require two distinct circuits? 4. E2.0 per suite electrical calculations and the Single Line diagrams, the 100 amp suite panel schedule is undersized. 5. E2.0 is missing Tucson City’s required short circuit calculations for the values shown. 6. E2.0 is missing EV panel on Single Line or is missing as a single line. 7. E2.0 is missing overcurrent protection for House Panel. Provide overcurrent protection with either meter CB or main circuit breaker. 8. E2.0 has 600-amp termination cabinet. However, this service shall be provided with a 600 amp disconnect to meet NEC 230.71 disconnect rule. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 9/2/2024 8:34:19 PM First Plumbing Review: 1). Plan pages A1.041 thru A1.06: Missing secondary scupper adjacent to primary scupper. Add required secondary scuppers. -2018 IPC 1106.5, 1108 2). Plan page P6.0: Fixture schedule Missing manufacturer names & model numbers. Add manufacturer names & model number or note stating fixtures will comply with- 2018 IPC 303 & 402.1 3). Plan Page P5.0 detail 204: Bottom fed Water heater detail Missing vacuum relief. Add vacuum relief valve in accordance with - 2018 IPC 504.2 4). Plan page P6.0: Fixture schedule missing shower/tub valve info. Add shower/tub valve info in accordance with -2018 IPC 412.3 |
||
| 09/16/2024 | Site Engineering | REQUIRES RESUBMIT | see zoning comments | ||
| 09/13/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-COM-0824-01612 - TD-DEV-0324-00079 3037 N BALBOA AV. – O-3 Multifamily (1st Review) TRANSMITTAL: September 13, 2024 Resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the O-3 zone (UDC 4.7.15). Food Service, Excluding Soup Kitchens is a allowed use in the zone (UDC Table 4.8-3). 1. Zoning has reviewed the building plan for compliance with development package (DP) TD-DEV-0324-00079 and although for the most part the plans match the following comment shall be addressed. Zoning cannot approve this building plan until the DP is approved by all review agencies. 2. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A, top of parapet. The development package shows the two-story height at 24’ and the building plan shows it at 24’-6” The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 09/13/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 08/16/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |