Permit Number: TC-COM-0824-01562
Parcel: 12509012A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0824-01562
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/28/2024 Commercial Electrical APPROVED
08/28/2024 Commercial Mechanical APPROVED
08/28/2024 Commercial Plumbing APPROVED
08/23/2024 Site Zoning APPROVED
08/31/2024 Water - PDSD APPROVED
08/27/2024 Site Engineering NOT REQUIRED
08/31/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
08/28/2024 Commercial Building REQUIRES RESUBMIT Sheet TS; For questions regarding Plan Review comments please contact: Dino M. Accardo, MCP, CBO, E: daccardo@willdan.com. Fire Plan Review is NOT within the scope of this review. All applicable comments will be followed with the initials, DMA.

1. Sheet TS; Provide complete existing building data, including but not limited to, separated or non-separated, sprinklered, fire alarm, etc... DMA
2. Sheet TS, 2018 IECC; Provide Mechanical and lighting certificates. DMA
3. Sheet A1.00, 2009 A117.1 902.1 General. Accessible dining surfaces and work surfaces shall comply with Section 902. Provide details that demonstrate compliance. DMA
4. Sheet A3.00, 2009 A117.1 604; Provide water closet fixture height and centerline and dimensions on plans. DMA
5. Sheet A3.00, 2009 A117.1 606; Provide lav heights and demonstrate compliance with this section. NOTE: Detail A on this sheet does not provide clear details to verify compliance. DMA
6. Sheet A3.00, 2018 IBC Ch 10; Provide main exit doors size on Door Schedule. Plan identifies as an 02 Door No. and a 2-6 door. DMA
08/26/2024 Fire New Construction REVIEW COMPLETED
08/12/2024 PDSD Application Completeness REVIEW COMPLETED