Permit Number: TC-COM-0824-01551
Parcel: 141185950

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0824-01551
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/21/2024 Commercial Electrical APPROVED
08/22/2024 Site Zoning APPROVED
08/27/2024 Site Engineering NOT REQUIRED
08/27/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/22/2024 Commercial Building REQUIRES RESUBMIT For inquiries on comments email ekulik@willdan.com
1. Sheet TS1 Correct the code addition of the plans. City of Tucson has adopted the 2018 I Codes and the 2017 NEC. Revise drawings as necessary.
2. Sheet A1.0 Provide Occupancy of the suite next door?
3. Sheet A1.1 The Demising wall is required to have 5/8 Drywall both sides.
4. Sheet A1.2 Show the required accessible path of travel to the accessible parking and public way. Per the IBC and ICC A117
5. Sheet A1.8 Show dimensions on enlarges restrooms floor plan.
6. Sheet E3.0 Provide lighting at required exit.
08/22/2024 Commercial Mechanical REQUIRES RESUBMIT 1. Sheet M2.0 Show the required outside air. (EK)
2. Sheet M2.0 Are the Heat Pumps existing or new? (EK)
08/22/2024 Commercial Plumbing REQUIRES RESUBMIT 1. Sheet P1.0 Provide a detail for repairing the slab at new underground Plumbing. (EK)
08/19/2024 Fire New Construction REVIEW COMPLETED
08/09/2024 PDSD Application Completeness Express REVIEW COMPLETED