Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0824-01533
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/21/2024 | Site Zoning | APPROVED | |||
09/03/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
09/03/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Please amend plans to provide a list (Sheet Index) that includes all the drawing sheets in this permit’s scope. IBC 107.2.1 2. Please amend plans to provide a detailed description of the work involved in this permit’s scope. IBC 105.3 Additionally, please include verbiage indicating this permit scope only includes roof framing, structural improvements, patching and reroofing existing RTU location, etc. The relocation of the RTU and resultant mechanical system modifications, will be by separate permit. IBC 107.2.1 3. Please amend plans to provide the method and materials used to patch existing abandoned roof opening. IBC 107.2.1 Additionally, provide framing and attachment details for RTU curb. 4. Please amend plans to specify the roofing system to be used along with details of the roofing system at the RTU curb. IBC 107.2.1 5. Please provide calculations used to design new roof opening and structural support for new RTU location to include the weight of the RTU. IBC 107.2.1 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
08/08/2024 | PDSD Application Completeness | REVIEW COMPLETED |