Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0824-01515
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/19/2024 | Commercial Electrical | APPROVED | |||
08/20/2024 | Commercial Plumbing | APPROVED | |||
08/16/2024 | Site Zoning | APPROVED | |||
08/20/2024 | Water - PDSD | APPROVED | |||
08/20/2024 | Site Engineering | NOT REQUIRED | |||
08/22/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/21/2024 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Sheet G1.1: Please provide Building Code Appeal number or apply for an appeal for the travel distance more than 100 feet. IBC Table 1007.2.1 Sheet G1.1: Please amend plan to add a detailed description of the work involved in this permit’s scope. IBC 105.3 Sheet G1.1: Please amend plans to provide a dimensioned architectural site plan, calling out property lines. IBC 107.2.6 Sheet G1.1: Please amend plans to provide dimensioned distances between structures and adjacent lot lines. IBC 107.2.6 Sheet G1.1: Please amend plans to show the fire-resistance rating of all exterior walls is shown and meets IBC Table 602. IBC 602.1 Additionally please indicate the fire rating and construction at the property lines between buildings. Sheet G1.1: Please amend plans to show the type of fire sprinkler system being used in this building. IBC 107.2.1 Sheet G1.1: Please amend plans to show the path(s) of exit discharge to a public way or a safe dispersal area. IBC 107.2.3, 1028.5 Sheet G1.1: Please indicate the changes in elevation < 12 inches use sloped surfaces along the path of exit discharge. IBC 1003.5 Sheet G1.1: Please amend plans to provide a photometric plan or other method of showing 1 footcandle of normal power illumination at the walking surface along the path(s) of exit discharge, while the building is occupied. IBC 1008.2.1, IBC 1008.2.3 Sheet G1.1 Amend site plan to show at least one accessible route within the site shall be provided from public transportation stops, accessible parking, accessible passenger loading zones, and public streets or sidewalks to the accessible building entrance served. IBC Section 1104.1 Sheet G1.1: IEBC 305.7 requires that accessibility be provided to the altered spaces. Where the existing path of travel elements, which entails a primary entrance, a primary path of travel, sanitary facilities serving the area, a drinking fountain, and signs. If these items are in full compliance with the current code, provide a statement indicating this on the cover sheet of the drawings. Otherwise, accessibility upgrades shall be required in accordance with IEBC.305.7. 1. If the cost of providing or upgrading the items above to be accessible is disproportionate to the cost of construction (exceeds 20% of the cost of construction not including accessibility upgrades), please provide information to verify construction costs. If this exemption is taken, accessibility upgrades equaling 20% of the cost of the project shall be made. Sheet A2.1: Amend plans to provide expand on the method used to block the use of the basement and stairs from being accessed and used. IBC 107.2.1 For example: Locking hardware and signage No Occupancy in Basement, possibly add a screened top IBC 107.2.1 Sheet A2.1: Please amend plans to provide transfer shower drawing to meet the requirements of 2009 ICC A117.1 610.3.2 The plans were marked up with code requirements for your use. Additionally, please identify the control wall on the plans. Sheet A2.1: Please amend plans to show the location and type of drinking fountain IBC 2902 or; When a single drinking fountain is required, it may be substituted with a point of use water cooler or dispenser. I could not find where the use of a break room sink is allowed as a substiture. Sheet S1.0: Please amend plans to provide a statement of special inspections for this project. IBC 1704.1 Additionally, please provide a list of special inspections for this project. IBC 1705.1 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
08/20/2024 | Commercial Mechanical | REQUIRES RESUBMIT | Provide heating and cooling load calculations to justify the heating/cooling capacities of the specified HVAC units. Reference: Section C403.1.1 and C502.2.3, IECC 2018. | ||
08/22/2024 | Fire New Construction | REQUIRES RESUBMIT | Resolve all building comments john.vincent@tucsonaz.gov 5203495581 |
||
08/05/2024 | PDSD Application Completeness | REVIEW COMPLETED |