Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0823-02100
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/02/2023 | Water - PDSD | APPROVED | |||
10/02/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
09/06/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/6/2023 2:47:48 PM See the building review comments. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/6/2023 2:46:21 PM 1) General: Provide the geotechnical engineer report for the soil bearing capacity. (2018 IBC section 1803.1) 2) General: Include the wall, roof, foundation perimeter, window and door insulation R-Values and U-factors showing compliance with the 2018 IECC section C402. 3) Sheet G001 (Project Details): Include the allowed vs actual area, height, and number of stories per the 2018 IBC Chapter 5. 4) Sheets P101 and P103 (Plumbing Details and Drawings): Hand sinks in kitchens are required to be connected to the grease interceptor or have a sign posted stating "HANDWASH SINK ONLY! NO FOOD PREPARATION OR DISHWASHING ALLOWED.” The hand sink in the corner of the kitchen is not connected to the grease interceptor. If connecting the sink to the grease trap, please revise the fixture calculations for the grease trap and revise all applicable sheets. (2018 IPC amended section 1003.3) 5) Sheets P101 and P103 (Plumbing Details and Drawings): Hydromechanical grease interceptors are only allowed when there are 4 or fewer fixtures. Please revise all applicable sheets and calculations using the Gravity Grease Interceptors Table. (2018 IPC amended section 1003.3) 6) Sheet E110 (Electrical One-Line Diagram): The feeders detailed are not large enough for 200amp subpanels and do not show a neutral conductor. Please show the correct conductors and sizes. (2017 NEC section 310.15) Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/6/2023 2:47:15 PM See the building review comments. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/6/2023 2:46:58 PM See the building review comments. Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/6/2023 2:47:30 PM See the building review comments. |
||
09/14/2023 | Site Engineering | REQUIRES RESUBMIT | 1. The permit cannot be approved until its associated development package, TD-DEV-0823-00364, has been approved. Lianne Evans lianne.evans@tucsonaz.gov |
||
09/21/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: TC-COM-0823-02100 – Salad and Go Building Plan Review (1st Review) 3805 E Broadway Bl / C-1 TRANSMITTAL DATE: 09/21/2023 1.COMMENT: Zoning has reviewed the building plans for compliance with the associated Development Package TD-DEV-0223-00141. Zoning cannot approve the building plans until the DP is approved. 2. COMMENT: Ensure building area and heights are consistent with those shown on the development package. 3. COMMENT: Once the plans have been reviewed and approved by PDSD Commercial Plan Reviewers and zoning has verified consistency with the DP, the building plans can be approved by zoning. Resubmittal instructions: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf If you have any questions about this transmittal, Contact Iman Monshizadeh at (520) 837-4082 or by email Iman.Monshizadeh@tucsonaz.gov |
||
09/07/2023 | Fire New Construction | REVIEW COMPLETED | |||
08/31/2023 | PDSD Application Completeness | REVIEW COMPLETED |