Permit Number: TC-COM-0823-02054
Parcel: 136130040

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-0823-02054
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/07/2023 Site Zoning APPROVED
11/28/2023 Water - PDSD APPROVED
12/20/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/04/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Madeline Nelson
mnelson@safebuilt.com
Approved
Reason:
Date Completed : 11/30/2023 6:52:35 PM


Building(B) Reviewer
Janet Matz
jmatz@safebuilt.com
Denied
Reason:
Date Completed : 12/3/2023 11:34:05 PM
1. Comment Addressed
2. Sheet T1.0. Update the sheet index to match the drawing titles in the set. The Mechanical, Plumbing and Electrical sheets do not coordinate with the index. (General Comment). Comment partially addressed. The sheet index indicates civil sheets C4.1, C4.2, and C4,3 that were not included with the set. Provide a full set that coordinates with the index.

3. Comment Addressed

4. Comment Addressed

5. Comment Addressed

6. Comment Addressed

7. Comment Addressed

8. Comment Addressed

9. Comment Addressed

10. Comment Addressed



Mechanical(M) Reviewer
Jorge Valido
jvalido@safebuilt.com
Approved
Reason:
Date Completed : 9/20/2023 9:07:22 AM




Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Approved with Comments
Reason:
Date Completed : 9/19/2023 9:17:55 AM
Electrical Review of Super Star Car Wash
By: Ron Ross PE

E1.0 SITE PLAN: Missing Keynote 10.

E1.1 SITE LIGHTING & POWER PLAN: Missing Keynote, 5 & 6 used in details 1&2.

E2.0 LIGHTING & POWER PLAN:

Missing Keynote 5 or mis-identified and should be Keynote 3.

Could not locate Power Keynotes 4 & 5.



Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Denied
Reason:
Date Completed : 11/30/2023 9:34:18 PM
Second plumbing review: Comments 5 & 8 remain
Resolved-1). plan set missing site utility piping plan pages C4.1, C4.2, C4.3 -IPC 106.3.1

Resolved-2). Plan set missing 11 of the 14 plumbing pages shown on plan page T1.0 -IPC 106.3.1

Resolved-3). Oil interceptor on plan pages P1.0 & P1.1 needs to be vented -IPC 1003.9

Resolved-4). Commercial Washing machine needs lint interceptor on plan page P1.1 -IPC 1003.6

5). Unresolved-The 2.5 " carwash connection on plan page P1.2 needs its own RPZ backflow -IPC 608.1** there needs to be an additional RPZ Backflow on the car wash line separate from the RPZ on main water @ bldg entrance **

Resolved-6). Water line to mat wash needs RPZ backflow on plan page P1.2 - IPC 608.1

Resolved-7), Washing machine on plan pages P1.2 & P1.3 needs to be piped with hot water. -IPC 607.1

8). Unresolved- Roof drain riser diagram on plan page P1.1 only shows 2 sets of roof drains, Roof plan on same page shows 3 sets. Diagrams need to correlate -IPC 106.3.1

Resolved-9). Roof drain riser diagram on plan page P1.1 needs to show the total GPM load at each set of roof drains, and each point of interconnection & termination. -IPC 1106.2

Resolved-10). Can't do complete plumbing review until all plan pages are present -IPC 106.3.1
12/20/2023 Site Engineering REQUIRES RESUBMIT 1. The dumpster enclosure on sheet A1.0 does not match the approved site plan in development package TD-DEV-0623-00289. Revise the sheet to match the approved site plan.

Lianne Evans
lianne.evans@tucsonaz.gov
11/27/2023 Fire New Construction REVIEW COMPLETED
11/22/2023 PDSD Application Completeness Express REVIEW COMPLETED