Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0823-02054
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/07/2023 | Site Zoning | APPROVED | |||
| 11/28/2023 | Water - PDSD | APPROVED | |||
| 12/20/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/04/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 11/30/2023 6:52:35 PM Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 12/3/2023 11:34:05 PM 1. Comment Addressed 2. Sheet T1.0. Update the sheet index to match the drawing titles in the set. The Mechanical, Plumbing and Electrical sheets do not coordinate with the index. (General Comment). Comment partially addressed. The sheet index indicates civil sheets C4.1, C4.2, and C4,3 that were not included with the set. Provide a full set that coordinates with the index. 3. Comment Addressed 4. Comment Addressed 5. Comment Addressed 6. Comment Addressed 7. Comment Addressed 8. Comment Addressed 9. Comment Addressed 10. Comment Addressed Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 9/20/2023 9:07:22 AM Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 9/19/2023 9:17:55 AM Electrical Review of Super Star Car Wash By: Ron Ross PE E1.0 SITE PLAN: Missing Keynote 10. E1.1 SITE LIGHTING & POWER PLAN: Missing Keynote, 5 & 6 used in details 1&2. E2.0 LIGHTING & POWER PLAN: Missing Keynote 5 or mis-identified and should be Keynote 3. Could not locate Power Keynotes 4 & 5. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 11/30/2023 9:34:18 PM Second plumbing review: Comments 5 & 8 remain Resolved-1). plan set missing site utility piping plan pages C4.1, C4.2, C4.3 -IPC 106.3.1 Resolved-2). Plan set missing 11 of the 14 plumbing pages shown on plan page T1.0 -IPC 106.3.1 Resolved-3). Oil interceptor on plan pages P1.0 & P1.1 needs to be vented -IPC 1003.9 Resolved-4). Commercial Washing machine needs lint interceptor on plan page P1.1 -IPC 1003.6 5). Unresolved-The 2.5 " carwash connection on plan page P1.2 needs its own RPZ backflow -IPC 608.1** there needs to be an additional RPZ Backflow on the car wash line separate from the RPZ on main water @ bldg entrance ** Resolved-6). Water line to mat wash needs RPZ backflow on plan page P1.2 - IPC 608.1 Resolved-7), Washing machine on plan pages P1.2 & P1.3 needs to be piped with hot water. -IPC 607.1 8). Unresolved- Roof drain riser diagram on plan page P1.1 only shows 2 sets of roof drains, Roof plan on same page shows 3 sets. Diagrams need to correlate -IPC 106.3.1 Resolved-9). Roof drain riser diagram on plan page P1.1 needs to show the total GPM load at each set of roof drains, and each point of interconnection & termination. -IPC 1106.2 Resolved-10). Can't do complete plumbing review until all plan pages are present -IPC 106.3.1 |
||
| 12/20/2023 | Site Engineering | REQUIRES RESUBMIT | 1. The dumpster enclosure on sheet A1.0 does not match the approved site plan in development package TD-DEV-0623-00289. Revise the sheet to match the approved site plan. Lianne Evans lianne.evans@tucsonaz.gov |
||
| 11/27/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 11/22/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |