Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0823-01957
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/18/2023 | Site Engineering | APPROVED | |||
10/18/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
10/04/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 9/2/2023 3:37:57 AM Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 10/2/2023 12:16:02 AM 1. A1.101- Provide a minimum of 18” on the latch side for door 4 from the equipment rm to the service bays. ICC A117.1 -2009 Figure 404.2.3.2. Spaces and elements within employee work areas shall be constructed so that individuals with disabilities can approach, enter, and exit the work area. 2018 IBC 1103.2.2. Comment addressed 2. A1.101- Provide details or notes indicating the minimum requirements for the new alternating tread stair. Note 16 indicates a specific manufacturer, however it is unknown if the device specified meets the minimum standards of 2018 IBC 1011.14. Comment addressed 3. A1.102- Clarify the distance from the top of the alternating stair to the wall at the top on the attic level floor plan. There is a minimum of 2’-11” is noted on the sides of the stair guards however the clear landing at the top is unknown. Comment addressed 4. A3.101- the building sections indicate that the attic storage area is to have a clear floor to ceiling height of 4’-7 ½”. To be used for storage, a minimum of not less than 7 feet is to be provided. Modify the drawings or remove the storage and occupancy from this area. 2018 IBC 1207.2. Comment partially addressed. The wall sections on sheet A4.102 still indicate storage in this area. Coordinate all drawings and details. Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/2/2023 12:08:01 AM Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 10/2/2023 12:07:49 AM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 9/27/2023 11:02:55 PM Second Plumbing review: Comments 2 & 3 remain 1). Resolved-On plan page G1.001-update the applicable codes to indicate the 2018 International Plumbing Code. 2). Unresolved-add Primary & overflow scupper detail to plan page A1.102 or A4.201 to show these are separate through wall scuppers at different heights. also if primary became blocked at parapet wall the separate secondary scupper is able to function independently. This isn't clear on detail 1 roof plan or page A.4.201 -IPC 1106.5 , 1108 3). Now that civil utility plan page 7 has been supplied it does not correlate with the sewer & water locations shown on plan page P1.01 and utility page 7 does not illustrate the continuation of water or sewer. -IPC 106.3.1 4).Resolved- Lavatory faucet on plan page P0.01 needs to be the automatic type- Tucson plumbing code amendment 419.6 5). Resolved-Add fixture spacing measurements to plan page P1.01 -IPC 404.2, 405.3.1 6).Resolved- Does air compressor require a hub drain for periodic discharge? if yes add to plans -IPC 106.3.1 |
||
09/26/2023 | Water - PDSD | REQUIRES RESUBMIT | Comment not addressed. [Initial comment: Show the location of the proposed water meter, backflow preventer, and the water service pipe on a site plan. Provide the size of the water meter serving this building, the size of the backflow preventer associated with the water meter, and the total water demand served by the water meter. Reference: Section 107.2.1 and 107.2.6, IBC 2018.] | ||
09/26/2023 | PDSD Application Completeness | REVIEW COMPLETED |