Permit Number: TC-COM-0823-01934
Parcel: 11606155A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0823-01934
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/09/2023 Site Zoning APPROVED
08/15/2023 Site Engineering NOT REQUIRED
09/15/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
09/15/2023 Commercial Structural REQUIRES RESUBMIT With the Zoning Department, ensure that you process the Request for Zoning Authority Clearance & submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. NOTE: If you are proposing 10 Adult Clients, please firmly state it within your Code Analysis. Occupancy Classification R-4 maximum allowable is 10 clients [Indicate whether it is Child Day Care, Adult Day Care, Assisted Living, Residential Care, Group Home, Behavioral Health, etc (ensure that your selection confirms what you selected from the City Zoning Code)]. Include a statement as part of your code analysis as to how the facility handles any persons receiving custodial care who require limited verbal or physical assistance responding to an emergency situation to complete building evacuation and self preservation. Specify Condition 1 or Condition 2 per IBC 310 (this will determine the type of fire sprinkler system the fire department will require). Do the clients reside at the facility on a 24-hour basis? NOTE: Submit a complete Egress Plan. 1.) On the Site Plan show/indicate the Accessible route from drop off location to the accessible entry door complying to IBC 106 & ANSI A117. In an Emergency, show/locate the gathering area where it is safe from danger minimum 50 ft away from structure per IBC 310.5. 2.) Indicate the clear opening of the doors complying to ANSI A117. 3.) Indicate the clear width of hallways. 4.) Show/locate the side & back grab bars at the Water Closet as well as at the Shower, make sure to indicate the installation of Structural Backer Board for these grab bars per IBC Chapter 11. 5.) Provide Emergency Escape & Rescue Openings per R310 at every bedroom/sleeping space. On the drawing adjacent to the opening(s), indicate the clear opening for both horizontally and vertically and provide the dimension from the finish floor to the bottom of the opening. Indicate if there are obstacles on either side of the opening. 6.) Fire Sprinkler is required per IBC 420 and processed as a separate permit. Submit the drawings to Tucson Fire Department for review and approval. They will conduct fire inspection, the inspection approval document will be required before issuing the Certificate of Occupancy. 7.) A fire alarm is required [IBC 907], If they exist...indicate them on your drawing. If not...please propose to install them. Illumination with emergency backup power is required in all components of the means of egress system [IBC 1008]. Please locate those equipments on your plan (to be inspected by Tucson Fire Department). Electrical work (conductors/wiring/breaker ONLY) related to the installation of Emergency Lights, Lighted Signs, Fire/Audible/Smoke Alarms/Fire Extinguisher will be inspected by City of Tucson inspectors, show on your plans so that our inspectors will know what wiring/breaker to inspect and shall also be reviewed as part of this permit. Any new renovation work must be included as part of this building permit. 8.) A Final inspection will be conducted by our inspectors prior to issuance of the Certificate of Occupancy. 9.) An Operator's License must be applied for with the State, the absence of this license shall void this building permit. 10.) Submit a draft copy of the State License application confirming the exact use title for the certificate of occupancy document.
08/14/2023 Fire New Construction REQUIRES RESUBMIT -I currently show a fire permit for fire sprinklers. TF-FCP-0723-00870. Your plans state no fire sprinklers. Please explain.
john.vincent@tucsonaz.gov
5203495581
09/12/2023 Water - PDSD REQUIRES RESUBMIT A residential care facility requires the installation of a reduced pressure zone backflow prevention assembly (RP). Show the location and size of the water meter, backflow preventer, and the water service pipe on the site plan. Reference: Section 107.2.1 and 107.2.6, IBC 2018.
08/09/2023 PDSD Application Completeness REVIEW COMPLETED