Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0823-01925
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/11/2023 | Water - PDSD | APPROVED | |||
09/11/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/24/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Denied Reason: Date Completed : 8/23/2023 3:43:26 PM 1. Provide Geotechnical Report for the proposed building per International Building Code 2018, Section 1803.1 as called out on General Notes sheet S0.01. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 8/11/2023 7:27:14 PM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 8/13/2023 7:21:27 PM No mechanical plans submitted no action required from mechanical Electrical(E) Reviewer Ron Ross rross@safebuilt.com Conditionally Approved Reason: Date Completed : 8/22/2023 8:25:22 AM Electrical Review of Grey Shell By: Ron Ross PE E2.02 FEEDER DIAGRAMS: Font issues with PDF or AutoCAD for a couple of notes. E2.03 PANEL SCHEDULES & DETAILS: Font issues with PDF or AutoCAD for a couple note on Schematic Feeder Wiring Diagram. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 8/23/2023 8:40:00 PM First Plumbing Review: 1). Hose bibs on plan pages P1.00 & P1.01 need shut off valves-IPC 606.2 2). Revise gas notes 11 on plan page P1.00 & P1.01 to state future gas will be capped in ceiling space-IFGC 404.15 3). Show or notate the sanitary vent be piped or connecting to a vent the extends to the exterior on plan pages P1.00 & P1.01 -IPC 904.3 |
||
08/09/2023 | Site Engineering | REQUIRES RESUBMIT | See Zoning Comment | ||
08/09/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-COM-0823-01925 2545 East Broadway Boulevard – C-1/R-2 Solot Redevelopment (1st Review) TRANSMITTAL DATE: August 9, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Zoning has reviewed the building plans for compliance with the associated development package TD-DEV-0423-00202. Although it appears the building plan footprint, building height, and square footage are consistent with the submitted development package, Zoning cannot approve the building plans until all review agencies have approved TD-DEV-0423-00202. Please note that the proposed shade canopy within the vehicular use area is not depicted on the development package drawings. The canopy is required to be included within the scope of work of the development package to be approved under TC-COM-0823-01925. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
08/25/2023 | Fire New Construction | REVIEW COMPLETED | |||
08/08/2023 | PDSD Application Completeness | REVIEW COMPLETED |