Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2023 Bldg Permits - Post Review REVIEW COMPLETED
09/11/2023 External Reviewers - SAFEBuilt REVIEW COMPLETED Structural(S) Reviewer
Daljit Benipal
dbenipal@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 8/16/2023 4:58:26 PM
NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall
not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances.




Building(B) Reviewer
Andrew Bevis
abevis@safebuilt.com
Approved
Reason:
Date Completed : 8/11/2023 10:52:01 AM



Mechanical N/A




Electrical N/A



Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 9/9/2023 9:48:58 AM
Second plumbing Review: OK SUBJECT TO FIELD INSPECTIONS
1). Resolved-the dog mister listed on plan CL-8 needs a detail added to plan page LD-2 -IPC 106.3.1

2). Resolved-the playground drinking fountain listed on CL-4 needs a detail added to plan page LD-2 -IPC 106.3.1

3). RESOLVED-add fixture schedule with manufacturer names & model numbers of the misters fountains shown on plan pages CL-4 & CL-8 - IPC 303 ** Based on product specifications on their respective web pages, the Pet fountain incorporates an internal backflow device, the Mister water outlets are located at a level to comply with an acceptable means of Air gap for backflow protection**

4). Resolved-Provided Tucson park ordinance that allows park fountains to discharge to earth. -IPC 301.3** PIMA County & Parks detail added to plan page LD-2 and detail submitted with document upload

5). Now that water connected equipment details have been added to Page LD-2 , All water connections at each device/appliance/apparatus will need an individual shut off valve- IPC 606.2 =Subject to field inspections**
09/08/2023 PDSD Application Completeness REVIEW COMPLETED