Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0726-01205
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/06/2026 | Site Engineering | NOT REQUIRED | |||
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction | PENDING ASSIGNMENT | |||
| N/A | Site Zoning | PENDING ASSIGNMENT | |||
| N/A | Water - PDSD | PENDING ASSIGNMENT | |||
| 08/11/2026 | Commercial Building | REQUIRES RESUBMIT | August 11, 2026 1st Review Intertech Architectural Interiors Attn: Erin Hastreiter 6089 E. Grant Rd Tucson, AZ 85712 Re: 5151 E. BROADWAY SUITE 1170 TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0726-01205 Stantec Project Number: 185215066 Stantec File Number: TUC-26-046 Plan review for the project referenced above has been completed. This letter reflects comments to be addressed. PLEASE send all responses to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B I-A 1,343 9 Yes Yes Separate Permits: Automatic fire sprinklers, fire alarm, and signage. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS General 1. Please indicate that the automatic fire sprinkler system [2024 IBC Sec. 903] and fire alarm system [2024 IBC Sec. 907] are to be provided as part of this project and are to be submitted as a separate permit (not a deferred submittal). This comment applies to this project because space is being reconfigured. 2. Please provide a written scope of work on the plans. 3. Please show all existing fire rated assemblies on the plan. Clearly show egress path from the suite to the nearest building exit. 4. It appears that one suite is being divided into two suites. Please confirm, and if that is the case, please state that on the plans in the requested “scope of work”. 5. Provide a signage plan and details demonstrating that office identification signage and other signage identifying permanent rooms or spaces will be compliant with [ICC/ANSI A117.1-2017 Sec. 703 and 2024 IBC Sec. 1112.6]. Sheet G1 1. General Notes item 12 states that all insulation shall comply with the 2012 IBC, the City of Tucson has adopted the 2024 IBC. Please correct the notes on the drawing to reflect the current code. STRUCTURAL COMMENTS None 1. Structural work does not appear to be indicated for this project. MECHANICAL COMMENTS Sheet M1 1. Outside Air Notes: Balancing will be required, please change the note that states otherwise. 2. The supply air in office 101 is from an a VAV that appears to be controlled by an adjacent office suite. Please clarify whether the thermostat for this unit is centrally controlled or is the thermostat controlled by the adjacent office suite. Thermostatic controls are required to be adjustable to control the zone in which they serve. [2024 IECC Sec C403.4.1] Please revise the design or clarify how the design complies with code. Sheet M2 1. Mechanical Notes 1.01: The City of Tucson has adopted the 2024 IECC. Please change the reference on the plans from the 2018 IECC to the 2024 IECC. PLUMBING COMMENTS Sheet P2 1. Please provide the total developed length for the vent for the breakroom sink. [2024 IPC Sec 906.1] ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Sherryn Hensley Senior Plan Examiner 480-687-6082 sherryn.hensley@stantec.com |
||
| 08/11/2026 | Commercial Electrical | REQUIRES RESUBMIT | August 11, 2026 1st Review Intertech Architectural Interiors Attn: Erin Hastreiter 6089 E. Grant Rd Tucson, AZ 85712 Re: 5151 E. BROADWAY SUITE 1170 TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0726-01205 Stantec Project Number: 185215066 Stantec File Number: TUC-26-046 Plan review for the project referenced above has been completed. This letter reflects comments to be addressed. PLEASE send all responses to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B I-A 1,343 9 Yes Yes Separate Permits: Automatic fire sprinklers, fire alarm, and signage. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS General 1. Please indicate that the automatic fire sprinkler system [2024 IBC Sec. 903] and fire alarm system [2024 IBC Sec. 907] are to be provided as part of this project and are to be submitted as a separate permit (not a deferred submittal). This comment applies to this project because space is being reconfigured. 2. Please provide a written scope of work on the plans. 3. Please show all existing fire rated assemblies on the plan. Clearly show egress path from the suite to the nearest building exit. 4. It appears that one suite is being divided into two suites. Please confirm, and if that is the case, please state that on the plans in the requested “scope of work”. 5. Provide a signage plan and details demonstrating that office identification signage and other signage identifying permanent rooms or spaces will be compliant with [ICC/ANSI A117.1-2017 Sec. 703 and 2024 IBC Sec. 1112.6]. Sheet G1 1. General Notes item 12 states that all insulation shall comply with the 2012 IBC, the City of Tucson has adopted the 2024 IBC. Please correct the notes on the drawing to reflect the current code. STRUCTURAL COMMENTS None 1. Structural work does not appear to be indicated for this project. MECHANICAL COMMENTS Sheet M1 1. Outside Air Notes: Balancing will be required, please change the note that states otherwise. 2. The supply air in office 101 is from an a VAV that appears to be controlled by an adjacent office suite. Please clarify whether the thermostat for this unit is centrally controlled or is the thermostat controlled by the adjacent office suite. Thermostatic controls are required to be adjustable to control the zone in which they serve. [2024 IECC Sec C403.4.1] Please revise the design or clarify how the design complies with code. Sheet M2 1. Mechanical Notes 1.01: The City of Tucson has adopted the 2024 IECC. Please change the reference on the plans from the 2018 IECC to the 2024 IECC. PLUMBING COMMENTS Sheet P2 1. Please provide the total developed length for the vent for the breakroom sink. [2024 IPC Sec 906.1] ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Sherryn Hensley Senior Plan Examiner 480-687-6082 sherryn.hensley@stantec.com |
||
| 08/11/2026 | Commercial Mechanical | REQUIRES RESUBMIT | August 11, 2026 1st Review Intertech Architectural Interiors Attn: Erin Hastreiter 6089 E. Grant Rd Tucson, AZ 85712 Re: 5151 E. BROADWAY SUITE 1170 TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0726-01205 Stantec Project Number: 185215066 Stantec File Number: TUC-26-046 Plan review for the project referenced above has been completed. This letter reflects comments to be addressed. PLEASE send all responses to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B I-A 1,343 9 Yes Yes Separate Permits: Automatic fire sprinklers, fire alarm, and signage. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS General 1. Please indicate that the automatic fire sprinkler system [2024 IBC Sec. 903] and fire alarm system [2024 IBC Sec. 907] are to be provided as part of this project and are to be submitted as a separate permit (not a deferred submittal). This comment applies to this project because space is being reconfigured. 2. Please provide a written scope of work on the plans. 3. Please show all existing fire rated assemblies on the plan. Clearly show egress path from the suite to the nearest building exit. 4. It appears that one suite is being divided into two suites. Please confirm, and if that is the case, please state that on the plans in the requested “scope of work”. 5. Provide a signage plan and details demonstrating that office identification signage and other signage identifying permanent rooms or spaces will be compliant with [ICC/ANSI A117.1-2017 Sec. 703 and 2024 IBC Sec. 1112.6]. Sheet G1 1. General Notes item 12 states that all insulation shall comply with the 2012 IBC, the City of Tucson has adopted the 2024 IBC. Please correct the notes on the drawing to reflect the current code. STRUCTURAL COMMENTS None 1. Structural work does not appear to be indicated for this project. MECHANICAL COMMENTS Sheet M1 1. Outside Air Notes: Balancing will be required, please change the note that states otherwise. 2. The supply air in office 101 is from an a VAV that appears to be controlled by an adjacent office suite. Please clarify whether the thermostat for this unit is centrally controlled or is the thermostat controlled by the adjacent office suite. Thermostatic controls are required to be adjustable to control the zone in which they serve. [2024 IECC Sec C403.4.1] Please revise the design or clarify how the design complies with code. Sheet M2 1. Mechanical Notes 1.01: The City of Tucson has adopted the 2024 IECC. Please change the reference on the plans from the 2018 IECC to the 2024 IECC. PLUMBING COMMENTS Sheet P2 1. Please provide the total developed length for the vent for the breakroom sink. [2024 IPC Sec 906.1] ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Sherryn Hensley Senior Plan Examiner 480-687-6082 sherryn.hensley@stantec.com |
||
| 08/11/2026 | Commercial Plumbing | REQUIRES RESUBMIT | August 11, 2026 1st Review Intertech Architectural Interiors Attn: Erin Hastreiter 6089 E. Grant Rd Tucson, AZ 85712 Re: 5151 E. BROADWAY SUITE 1170 TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0726-01205 Stantec Project Number: 185215066 Stantec File Number: TUC-26-046 Plan review for the project referenced above has been completed. This letter reflects comments to be addressed. PLEASE send all responses to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B I-A 1,343 9 Yes Yes Separate Permits: Automatic fire sprinklers, fire alarm, and signage. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS General 1. Please indicate that the automatic fire sprinkler system [2024 IBC Sec. 903] and fire alarm system [2024 IBC Sec. 907] are to be provided as part of this project and are to be submitted as a separate permit (not a deferred submittal). This comment applies to this project because space is being reconfigured. 2. Please provide a written scope of work on the plans. 3. Please show all existing fire rated assemblies on the plan. Clearly show egress path from the suite to the nearest building exit. 4. It appears that one suite is being divided into two suites. Please confirm, and if that is the case, please state that on the plans in the requested “scope of work”. 5. Provide a signage plan and details demonstrating that office identification signage and other signage identifying permanent rooms or spaces will be compliant with [ICC/ANSI A117.1-2017 Sec. 703 and 2024 IBC Sec. 1112.6]. Sheet G1 1. General Notes item 12 states that all insulation shall comply with the 2012 IBC, the City of Tucson has adopted the 2024 IBC. Please correct the notes on the drawing to reflect the current code. STRUCTURAL COMMENTS None 1. Structural work does not appear to be indicated for this project. MECHANICAL COMMENTS Sheet M1 1. Outside Air Notes: Balancing will be required, please change the note that states otherwise. 2. The supply air in office 101 is from an a VAV that appears to be controlled by an adjacent office suite. Please clarify whether the thermostat for this unit is centrally controlled or is the thermostat controlled by the adjacent office suite. Thermostatic controls are required to be adjustable to control the zone in which they serve. [2024 IECC Sec C403.4.1] Please revise the design or clarify how the design complies with code. Sheet M2 1. Mechanical Notes 1.01: The City of Tucson has adopted the 2024 IECC. Please change the reference on the plans from the 2018 IECC to the 2024 IECC. PLUMBING COMMENTS Sheet P2 1. Please provide the total developed length for the vent for the breakroom sink. [2024 IPC Sec 906.1] ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Sherryn Hensley Senior Plan Examiner 480-687-6082 sherryn.hensley@stantec.com |
||
| 08/05/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |