Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0726-01155
Parcel: 10408075B

Address:
4495 N ORACLE RD

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0726-01155
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/27/2026 Commercial Electrical APPROVED
08/04/2026 Site Zoning APPROVED
08/05/2026 Water - PDSD APPROVED
07/24/2026 Site Engineering NOT REQUIRED
08/05/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/05/2026 Commercial Building REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0726-01155
ADDRESS/PARCEL: (4495 N ORACLE RD TUCSON, AZ 85705)
TC-COM-0526-00787 (3002 E GRANT RD Unit:UNIT 2 TUCSON, AZ 85716)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.

Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.

COMMENTS:
1. NEW HOOD
a. Provide structural detail drawings as to how the Hood and the Grease Duct are supported, this also applies to the upblast exhaust fan.
i. Provide Structural Calculation for the items listed above.
ii. Both drawings and calculations above must bear the structural engineer’s seal/signature/date signed.
2. SHEET MP2.0
a. Keyed Notes #14: Add a note indicating the studs used on the non-combustible wall must be of metal studs.
3. Please resubmit.
08/05/2026 Commercial Mechanical REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0726-01155
ADDRESS/PARCEL: 4495 N ORACLE RD TUCSON, AZ 85705

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Please provide an air balance schedule showing the total supply and exhaust airflow quantities for the building. Demonstrate that the proposed HVAC systems maintain the 150 CFM net positive building pressure. Reference: Section 508.1.3, IMC 2024.
08/05/2026 Commercial Plumbing REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0726-01155
ADDRESS/PARCEL: 4495 N ORACLE RD TUCSON, AZ 85705

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Please show all other gas-fired appliances connected to the gas meter as well and the total gas demand seen by the meter. Verify the existing gas piping system is adequately sized for the replacement fryer. Reference: Section 402, IFGC 2024.
08/04/2026 Fire New Construction REVIEW COMPLETED
07/23/2026 PDSD Application Completeness Express REVIEW COMPLETED