Permit Number: TC-COM-0726-01092
Parcel: 14002002C

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0726-01092
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/07/2026 Site Zoning Standard APPROVED
08/06/2026 Water - PDSD Standard APPROVED
08/04/2026 Commercial Building Standard NOT REQUIRED
08/06/2026 Commercial Mechanical Standard NOT REQUIRED
08/06/2026 Commercial Plumbing Standard NOT REQUIRED
08/10/2026 Fire New Construction Standard NOT REQUIRED
08/10/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/03/2026 Commercial Electrical Standard REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0726-01092 (4350 E IRVINGTON RD TUCSON, AZ 85714)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Provide the correct code references on the provided plans. Show compliance with the currently adopted codes.
2. Provide Ground-Fault Protection of Equipment for the 1200A Switchboard, per NEC 230.95.
3. Reference Sheet EV02.1, Wire Tag #2 and 'EV Main Service' main breaker. The provided conductor sizes are undersized for the given 1200A main breaker. NEC 240.4.
4. Reference Sheet EV02.2, Pannelboard 'EV' Schedule, circuits 7,9,11. The line diagram on sheet EV02.1 shows this connection from 'EV' to Panel EV3 with a 600A C/B. Please correct and show consistent information.
08/03/2026 Outdoor Lighting Standard REQUIRES RESUBMIT Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. The replacement, relocation and installation of new lighting fixtures requires compliance with the City of Tucson Outdoor Lighting Code.
Note or clarify if there are any changes to the excising outdoor lighting.
08/04/2026 Site Engineering Standard REQUIRES RESUBMIT Site Engineering Review

TC-COM-0726-01092
4350 E IRVINGTON RD

Date of Transmission: 8/4/2026

Description: Install 1-1200amp service, 1-750kva transformer,1-2000amp panelboard, 4-400amp panelboards,1-600amp panelboard, 1-200amp panelboard and 19 new electric vehicle chargers and associated conduit and wiring.

Site Engineering comments are as follows:

1. A Development Package is required for the scope of this project. The content requirements may be found in Administrative Manual Section 2-06. The Development Package is a separate submission and must be approved by all reviewers prior to the approval of this commercial permit.
2. Additional comments may be forthcoming depending on the content of files submitted for subsequent review cycles.

*Please submit revised drawings along with a detailed response letter stating how each resubmittal comment has been addressed*

To re-submit, visit the Tucson Development Center Online at:
https://tdc-online.tucsonaz.gov/#/home

The instructions for resubmittal can be found at: Revisions and Resubmittals

Engineering Associate: Ryan Insalaco
ryan.insalaco@tucsonaz.gov
07/20/2026 PDSD Application Completeness Express REVIEW COMPLETED