Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-COM-0726-01030
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/07/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/07/2026 | Commercial Electrical Express | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Temporary Installation The plans indicate the proposed sleeping cabin is a temporary demonstration unit. Please note on the plans that the electrical installation is temporary and shall comply with the requirements of 2023 NEC Article 590. Indicate the intended duration of the temporary installation and provide a statement that the electrical installation will be removed upon completion of the demonstration. 2. Existing Service Capacity Provide electrical load calculations demonstrating that the existing building service and feeder have sufficient capacity to serve the additional temporary demonstration cabin load in accordance with NEC Article 220. 3. Electrical Site Plan Provide a site plan indicating: • Existing building service equipment • Source of power • Temporary feeder routing • Disconnect location • Cabin location • Wiring method between the building and demonstration cabin 4. Feeder and Overcurrent Protection Provide conductor sizes, insulation type, wiring method, overcurrent protection, and voltage rating for the temporary feeder supplying the demonstration cabin. 5. Disconnecting Means Provide a readily accessible disconnecting means for the temporary cabin in accordance with NEC Articles 225 and 590. 6. Grounding and Bonding Provide grounding and bonding details for the temporary feeder, including equipment grounding conductor sizing and termination in accordance with NEC Article 250. 7. Wiring Method Indicate the temporary wiring method. Temporary wiring shall comply with NEC Article 590 and be protected from physical damage. If flexible cord is proposed, demonstrate compliance with NEC Article 400 and Article 590. 8. GFCI Protection Provide GFCI protection for all receptacles required by NEC 210.8 and any temporary receptacles required by NEC 590. 9. Protection from Physical Damage Show how temporary conductors or cords crossing walkways or drive aisles will be protected from physical damage and trip hazards. 10. Weatherproof Equipment All exterior receptacles, cord connections, boxes, and equipment shall be listed for wet or damp locations and provided with weatherproof covers where required. 11. Electrical Floor Plan Provide a floor plan of the demonstration cabin indicating lighting outlets, receptacles, equipment, panelboard (if provided), and circuit layout. 12. Label Temporary Installation Add a note to the plans stating: "This electrical installation is for a temporary demonstration sleeping cabin only and shall be removed upon termination of the demonstration in accordance with 2023 NEC Article 590." 13. Working space Show the working space about the service equipment for the cabin, e.g. Temp Panel Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 07/06/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |