Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0725-01417
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/12/2025 | Commercial Building | APPROVED | |||
| 08/06/2025 | Commercial Electrical | APPROVED | |||
| 08/08/2025 | Site Zoning | APPROVED | |||
| 08/13/2025 | Water - PDSD | APPROVED | |||
| 08/13/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/13/2025 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Provide information on the sequence of operation for the restroom exhaust fans to show that all of the air supplied to the restrooms will be exhausted. Reference: Section 403.2.1 (4), IMC 2018. 2. Provide smoke detectors in the return air duct, upstream of any outside air connections, for all air distribution systems moving than 2,000 CFM. A smoke detector may be installed in the supply duct per Mechanical General Notes #16 but only in addition to the required smoke detector in the return duct. Reference: Section 606.2.1, IMC 2018, as amended by the City of Tucson. |
||
| 08/13/2025 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Provide a design for the mounting shelf for the water heater along with structural calculations to show that the water heater is safely supported from the building structure. Reference: Section 301.2, IPC 2018. 2. Provide a metering faucets for the lavatories, LV-1, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10 seconds. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 3. Detail 5/P6.1 shows a bottom-fed Provide specifications for the “water dispenser”, WD-1, noted on sheets P0.1 and P2.1. The use of a point-of-use water dispenser in lieu of a drinking fountain requires the installation of a listed and labeled dispenser that is permanently connected to the water distribution system, along with a permanently mounted disposable cup dispenser. The cup dispenser shall be located adjacent to the water dispenser with the dispensing end between 34” and 48” above the finished floor. See: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/2008-21_e_drinkingfountainpolicy.pdf 4. storage type water heater located above fixture outlets. Provide an approved vacuum relief valve per the manufacturer’s listing information, i.e. with no valves located between the vacuum relief valve and the water heater.. Reference: Section 504.2, IPC 2018. 5. Keynote 7 on P2.1 calls for a “…combined drain line for pressure and relief valve…” The discharge piping for a temperature and pressure relief valve shall not connect to piping serving any other equipment or relief valves. Reference: Section 504.6 (4), IPC 2018. 6. Revise the design of the recirculating hot water system so that the distance from the hot water source (i.e., the recirculating loop) to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018. |
||
| 08/07/2025 | Fire New Construction | REVIEW COMPLETED | |||
| 07/28/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |