Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0725-01416
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/07/2025 | Fire New Construction | NOT REQUIRED | |||
| 08/01/2025 | Site Engineering | NOT REQUIRED | |||
| 08/12/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/12/2025 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0725-01416 ADDRESS/PARCEL: (1468 W MIRACLE MILE TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. Please submit the Roof Plan to include the equipment on the roof such as HVAC, exhaust fan, electrical lines, etc. 2. Submit the Manual J (cooling and heating design for the home). Locate and label the outdoor unit and indoor unit if applicable, the supply registers, the return air, exhaust fans, etc. on the plans. 3. Dimensioned Floor Plan: The North arrow is pointing in the wrong direction. Please correct. 4. Locate and label the smoke alarm system on the plans the electrical receptacles complying to the code required distances of maximum 12 ft on center and maximum 6 ft from a door opening, etc. 5. Show the route of the Dryer exhaust line on the plan and its size. 6. Show the landing outside the doors. If it does not exist, please install along with the switched exterior door light (if it does not exist, please install one). 7. Locate/label the parking stalls associated with this home on the site plan. 8. Locate/label the exterior hose bib that is code compliant. 9. Provide the R value for the roof and the walls. 10. Identify the materials used on the exterior of the home as well as the roofing materials used. If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 08/05/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0725-01416 (1468 W MIRACLE MILE TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC) International Building Code (IBC), 2017 National Electrical Code (NEC). 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 2. Provide an electrical plan showing any/all electrical work and ‘as-built conditions’. Plans shall include, but may not be limited to items below: 3. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. 4. Show all wiring methods in detail for all new or modified branch circuit conductors and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4. 5. Provide a panel schedules, showing the circuits that are being modified, added or removed or existing. NEC arts;300 and 408.4. Include panel bus rating and A.I.C. rating. 6. Designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each existing, new or modified light fixture, receptacle, and equipment disconnect switch, NEC arts;300 and 408.4. 7. Show locations of each smoke alarm, IRC R310 [NFPA 72]. Notate that all smoke alarms must be interconnected with a power source from the building wiring and be equipped with battery backup. 8. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, [NEC 210.52(C)(1)] and [NEC 210.52(B)(1)]. GFCI protected, [NEC 210.8(A)]. 9. Show a receptacle outlet within 3’ of each lavatory basin in each bathroom, [NEC 210.52(D)]. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, [NEC 210.11(C)(3)] and [NEC 210.52(D)]. GFCI Protected, [NEC 210.8(A)]. 10. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, and bathrooms) including receptacles, lights and smoke detectors require combination type arc-fault circuit interrupters, [210.12(A)]. Additional comments may be forthcoming with a full-built electrical plan-set. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/12/2025 | Commercial Mechanical | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0725-01416 ADDRESS/PARCEL: (1468 W MIRACLE MILE TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. Show the location and size of buildings utility meters - gas, water, electric and sewer from property line to building. Section 107.2.1, IBC 2018 2. The submitted documents do not adequately show the scope of work for this address or how any intended changes will comply with the adopted building codes. Plans are to be sealed by an Arizona Registrant. Section 107.1, IBC 2018 3. Provide all mechanical and plumbing plans along with calculations (sheets M1.0 and P1.0 are missing). Section 107.1, IBC 2018 |
||
| 08/12/2025 | Commercial Plumbing | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0725-01416 ADDRESS/PARCEL: (1468 W MIRACLE MILE TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. Show the location and size of buildings utility meters - gas, water, electric and sewer from property line to building. Section 107.2.1, IBC 2018 2. The submitted documents do not adequately show the scope of work for this address or how any intended changes will comply with the adopted building codes. Plans are to be sealed by an Arizona Registrant. Section 107.1, IBC 2018 3. Provide all mechanical and plumbing plans along with calculations (sheets M1.0 and P1.0 are missing). Section 107.1, IBC 2018 |
||
| 08/08/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-COM-0725-01416 1468 W. Miracle Mile - MH-1 Convert Existing Office to Residence ( 1st Review) TRANSMITTAL DATE: August 8, 2025 Provide a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the MH-1 zone (UDC 4.7.10). A Mobile Home Park is a permitted use in this zone (Table 4.8-2). 1. Per UDC Table 6.3-2.A the allowed density for a Mobile Home Park in the MH-1 zone is 8 units per acre. Based on 1.24 acres the allowed number of units on this site is 9. The proposed conversion exceeds the allowed density and will require a rezoning to MU. Rezoning requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Entitlements#section-3. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 08/12/2025 | Water - PDSD | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0725-01416 ADDRESS/PARCEL: (1468 W MIRACLE MILE TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. Show the location and size of buildings utility meters - gas, water, electric and sewer from property line to building. Section 107.2.1, IBC 2018 2. The submitted documents do not adequately show the scope of work for this address or how any intended changes will comply with the adopted building codes. Plans are to be sealed by an Arizona Registrant. Section 107.1, IBC 2018 3. Provide all mechanical and plumbing plans along with calculations (sheets M1.0 and P1.0 are missing). Section 107.1, IBC 2018 |
||
| 07/28/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |