Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.2
Permit Number - TC-COM-0725-01382
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/26/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/25/2025 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Please provide the structural calculations; sealed by an Arizona licensed design professional, used to design the ramada construction with the next submittal. IBC 107.2.7 2. Please provide a statement of special inspections for this specific to this pro, as well as listing the required special inspections and test required for each special inspection. IBC 107.2.1, IBC 1704, IBC 1705 3. Sheet S3.0: Please amend the plans to provide drawings and details for the roof drainage. IBC 107.2.1 The method cannot be determined and the detail callout reference 2/S1.0 appears to be a footing detail. 4. Sheet S2.0: Please review and update the Detail Keynotes for clarity. IBC 107.2.1 For example. Keynote 13. BOND BREAKER. And it appears to be pointing to vertical rebar Keynote 14. 4” #2500 CONCRETE SLAB OVER 4" AB COMPACTED 98%. the arrow is pointing to the masonry column. Keynote 15. BEAM-REFER TO FRAMING PLAN (SHEET S1.1) FOR SIZE. Is indicated twice and appears to be pointing towards expansion joint material on the second listing Keynote 17. SIMPSON 'LU210Z' JOIST HANGER @ EA. RAFTER. Appears to be pointing towards the floor slab. 5. Please provide a code analysis for the new structure, indicating Construction type, Occupancy, square footage, number of occupants, Fire sprinklers Yes,No, etc. IBC 107.2.1 |
||
| 08/26/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0725-01382 841 E BANTAM RD. – R-2 Religious Use - Open Ramada Addition on the rear of the building (1st Review) TRANSMITTAL DATE: August 26, 2025 COMMENTS: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. This site is located in the R-2 zone (UDC 4.7.9). Religious Use is a permitted use in this zone (Table 4.8-2). 1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 08/25/2025 | Fire New Construction | REVIEW COMPLETED | |||
| 08/12/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |