Permit Number: TC-COM-0725-01381
Parcel: 117160090

Address:
197 E TOOLE AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0725-01381
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/31/2025 Site Engineering Standard APPROVED
07/21/2025 Fire New Construction Standard NOT REQUIRED
08/11/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/08/2025 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
1. Please amend the drawings so the ramp landing allows door maneuvering clearance. A parallel approach from the latch side of a pull door requires 24” of landing before the door opening. See Table and Figure 404.2.3.2 Maneuvering Clearance at Manual Swinging Doors.
2. Please amend plans to provide information about swinging door hardware. IBC 107.2.1 When traveling from the interior to the swinging door, if there is a closer and a latch 12” of maneuvering clearance will be required for a front approach on the latch side of the door. See Table and Figure 404.2.3.2 Maneuvering Clearance at Manual Swinging Doors.
3. The interior ramp landing is required to be 60 inches in length it is only shown as 4’- 4”. Please amend plans to comply with 2009 ICC A117.1 405.7.2
Please contact me if you have any questions about these comments.
4. Please amend plans to Provide illumination for the means of egress, including the exit discharge per IBC 1008. Show compliance with the following:
A. The means of egress shall be illuminated at all times the building space is occupied.
B. The means of egress illumination level shall not be less than 1 foot-candle at the walking surface.
C. The means of egress illumination shall be supplied by backup power (consisting of storage batteries, unit equipment, or an on-site generator) for a duration of not less than 90 minutes. IBC 1008.3

Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
08/11/2025 Site Zoning Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Krista Hansen
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-COM-0725-01381
197 E TOOLE AV
Commercial Addition/Alteration (1st Review)

TRANSMITTAL DATE: 8/11/2025


This site is zoned I-1 (UDC Section 4.7.29). Retail Trade, General Merchandise Sales (Art Gallery) is an allowed use in this zone (UDC Table 4.8-5).


Resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

1. The submitted plans include an exterior ADA accessible ramp area where none existed before. Per UDC 3.3.3.G.2.c., a development package is required on a commercial site when there is a "reconfiguration of an area outside of a building". Please submit a development package that meets the requirements indicated at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Development-Package. Site Zoning approval of this building permit cannot occur until the development package is first approved.

2. Work proposed along 6th Ave appears to be within the right-of-way (ROW). Contact Real Estate at Real.Estate@tucsonaz.gov to determine if a ROW use permit and temporary revocable easement (TRE) are required, and to secure applicable permits/easements.

3. Please clarify how the roll up door along Toole Ave will be accessed with the proposed stairs.

For questions regarding Zoning comments, please contact me at: Krista.Hansen@tucsonaz.gov
07/18/2025 PDSD Application Completeness Express REVIEW COMPLETED