Permit Number: TC-COM-0725-01360
Parcel: 13324005E

Address:
450 N PANTANO RD

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0725-01360
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/07/2025 Commercial Building Standard APPROVED
08/01/2025 Commercial Electrical Standard APPROVED
08/07/2025 Commercial Mechanical Standard APPROVED
08/07/2025 Commercial Plumbing Standard APPROVED
08/07/2025 Water - PDSD Standard APPROVED
07/23/2025 Outdoor Lighting Standard NOT REQUIRED No modification to the outdoor lighting.
08/05/2025 Site Engineering Standard NOT REQUIRED
08/07/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/02/2025 Fire New Construction Standard REQUIRES RESUBMIT -Existing gate on NW side of property does not swing in the direction of egress travel. This gate is part of the means of egress that leads to a public way and should have panic hardware. Correct the direction of swing and indicate the hardware type.
IFC 1010.1.2.1, 1010.2.8, 1010.4,
-Fire dept. knox box will be required on front of building if you don't already have one. Please make note on plans that TFD knox box will be installed.
-IFC 907.2.3. A manual fire alarm system utilizing an emergency voice/alarm communication system is required. Make a note on plans that a fire alarm system will be installed per IFC 907.2.3 and NFPA 72.
john.vincent@tucsonaz.gov
5203495581
08/06/2025 Site Zoning Standard REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0725-01360 - TD-DEV-0725-00183
450 N PANTANO RD. – O-3
Educational Use: Elementary and Secondary (1st Review)

TRANSMITTAL: August 6, 2025

Resubmittal requires a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the O-3 zone (UDC 4.7.15). Educational Use: Elementary and Secondary is an allowed use in the Zone, (UDC Table 4.8-3). See Use-Specific Standards 4.9.3.D and 4.9.13.K.

1. Zoning has reviewed the bulding plan for compliance with development package (DP) TD-DEV-0725-00183 and although it appears the plans are in compliance with each other until the DP is approved by all review agencies Zoning cannot approve this pemrit.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
07/16/2025 PDSD Application Completeness Express REVIEW COMPLETED