Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.2
Permit Number - TC-COM-0725-01292
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/29/2025 | Site Zoning | APPROVED | |||
| 07/30/2025 | Site Engineering | NOT REQUIRED | |||
| 07/31/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/28/2025 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Sheet G100: Please amend the plans to include a list that includes all the drawing sheets in this permit’s scope. IBC 107.2.1 Sheet G100: 2. Sheet G100: Please include 2009 ICC A117.1 Accessibility Code (by reference) to the list of applicable codes. IBC 107.2.1 2. Sheet G100: The project scope indicates “New ADA restrooms to be Constructed as a part of the permit”. Did the existing space have restrooms and these are replacing the existing restrooms and being upgraded to being accessible, or are these rest rooms new to this space? IBC 107.2.1 3. Please provide an existing/demo building plan to show existing conditions and any demolition to occur with this Tenant Improvement. IBC 107.2.1 4. Sheet G101: Please show clear floor space centered in front of the breakroom sink. If there is a front approach, please show the required knee and toe clearance. 2009 ICC A117.1 5. Sheet G101: Please provide plumbing information as referenced in the New Keynotes note # 10. IBC 107.2.1 6. Sheet G101: Please explain or update the Building Net square footage shown in the Occupant load area, as it is larger than the gross square footage. IBC 107.2.1 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 07/21/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0725-01292 (2660 N 1ST AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Provide complete electrical plans for all new electrical work per sheet G101, New Keynotes #1. 2. Provide Fault Current Analysis and show new equipment AIC rating sufficient to withstand the calculated Fault Current. Provide Available Fault Current calculations from TEP transformers to all new equipment, 2017 NEC 110.24. 3. Show new Panels and other new equipment with AIC ratings greater than or equal to the Available Fault Currents calculated, 2017 NEC 110.10. 4. Provide an updated panel schedule, showing the circuits that are being modified, added or removed. NEC arts;300 and 408.4. 5. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 07/31/2025 | Commercial Mechanical | REQUIRES RESUBMIT | Provide a mechanical design performed by an Arizona registrant who has demonstrated proficiency through registration, education, technical knowledge, or experience to perform such work. Reference: Sections 107.1 and 107.2.1, IBC 2018. | ||
| 07/31/2025 | Commercial Plumbing | REQUIRES RESUBMIT | Provide a plumbing design performed by an Arizona registrant who has demonstrated proficiency through registration, education, technical knowledge, or experience to perform such work. Reference: Sections 107.1 and 107.2.1, IBC 2018 | ||
| 07/31/2025 | Water - PDSD | REQUIRES RESUBMIT | Show the location and size of the existing water meter, backflow preventer, and the water service pipe on a site plan. Reference: Section 107.2.1 and 107.2.6, IBC 2018. | ||
| 07/30/2025 | Fire New Construction | REVIEW COMPLETED | |||
| 07/17/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |