Permit Number: TC-COM-0724-01457
Parcel: 11204201A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0724-01457
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/14/2024 Water - PDSD APPROVED
08/15/2024 Site Engineering NOT REQUIRED
08/21/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/21/2024 External Reviewers - Stantec REQUIRES RESUBMIT August 7, 2024
1st Review

Architects Studio, Inc.
Attn: Philip Veneziano
5931 East Pima Street #141
Tucson, Arizona 85712

Re: BLUE DOOR PSYCHOTHERAPY
TENAT IMPROVEMENT

City of Tucson Permit Number: TC-COM-0724-01457
Stantec Project Number: 185215066
Stantec File Number: TUC-24-104

Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
B V-B 1,357 9 Yes No
Separate Permits: Automatic fire sprinklers.
Deferred Submittals: None.
Special Inspections: None.

ARCHITECTURAL COMMENTS

General

1. Please indicate that the existing automatic fire sprinkler system modification [2018 IBC Sec. 903] is to be provided as part of this project and are to be submitted as a separate permit (not a deferred submittal).

STRUCTURAL COMMENTS

There are no comments.

MECHANICAL COMMENTS

General

1. Please provide an energy conservation compliance report for the new mechanical system. [Ref. IECC 2018 Sec. C403]

PLUMBING COMMENTS

There are no comments.

ELECTRICAL COMMENTS

There are no comments.


Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline.

Plans reviewed by:
Trevor Bies,
Senior Plan Reviewer
602-338-9922
trevor.bies@stantec.com
08/13/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0724-01457
2618 E FORT LOWELL RD. – C-1
TI – Medical Service Outpatient ( 1st Review)

TRANSMITTAL: August 13, 2024
This site is located in the C-1 zone (4.7.20). Medical Service Outpatient is a permitted use in the zone (UDC Table 4.8-4) subject to Use Specific Standards 4.9.4.O.2 and 4.9.13.O.

1. Based on aerial photographs there additions to the rear of the structure that show up some time after 2018 and are not shown on the last approved development package DP18-0080. Either 1) provide an approved DP that shows all structures on site, 2) provide photo documentation that shows that all structures have been removed to match DP18-0080, or 3) submit a DP and building plans for these structures.

2. Per discussions with Zoning Administration staff the proposed use is Medical Service Outpatient. The last approved use, DP18-0080 was General Merchandise Sales. Clearly demonstrate that the vehicle parking requirements for Medical Service Outpatient are met.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
08/09/2024 Fire New Construction REVIEW COMPLETED
07/30/2024 PDSD Application Completeness Express REVIEW COMPLETED