Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0724-01411
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/21/2024 | Commercial Electrical | APPROVED | |||
08/22/2024 | Commercial Mechanical | APPROVED | |||
08/22/2024 | Commercial Plumbing | APPROVED | |||
08/21/2024 | Site Zoning | APPROVED | |||
08/26/2024 | Site Engineering | NOT REQUIRED | |||
08/26/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/23/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Please amend drawings to show the court enclosure, type and connections. If over 6 feet in height provide calculations to show the system has adequate strength and stiffness to resist the loads to which they are subjected but not less than a horizontal load of 5 psf. IBC 1607.15 2. Please amend plan to resolve the apparent dead end corridor exceeding 20 feet, south of court eleven (11) IBC 1020.4 3. Please amend plan to provide Means of egress illumination and emergency lighting in the case of power failure. IBC section 1008. 4. IEBC 305.7 requires that accessibility be provided to the altered spaces. Where the existing path of travel elements, which entails a primary entrance, a primary path of travel, sanitary facilities serving the area, a drinking fountain, and signs. If these items are in full compliance with the current code, provide a statement indicating this on the cover sheet of the drawings. Otherwise, accessibility upgrades shall be required in accordance with IEBC.305.7. 1. If the cost of providing or upgrading the items above to be accessible is disproportionate to the cost of construction (exceeds 20% of the cost of construction not including accessibility upgrades), please provide information to verify construction costs. If this exemption is taken, accessibility upgrades equaling 20% of the cost of the project shall be made. Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
08/22/2024 | Fire New Construction | REQUIRES RESUBMIT | Verify whether or not there is an existing building fire alarm. Per IFC 907.2.1, a building fire alarm is required base on your OL > 300. john.vincent@tucsonaz.gov 5203495581 |
||
07/24/2024 | PDSD Application Completeness | REVIEW COMPLETED |