Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0724-01411
Parcel: 11706319B

Address:
300 S TOOLE AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0724-01411
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/26/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
09/26/2024 Commercial Structural REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.
1.Please amend drawings to show the court enclosure, type and connections. If over 6 feet in height provide calculations to show the system has adequate strength and stiffness to resist the loads to which they are subjected but not less than a horizontal load of 5 psf. IBC 1607.15
Comment partially satisfied: Please provide drawings and calculations showing compliance with 2018 IBC and sealed by an Arizona licensed design professional. For example, the submitted documents are sealed under Florida and the design criteria indicated 2020 Florida Building Code
2. Please amend plan to resolve the apparent dead end corridor exceeding 20 feet, south of court eleven (11) IBC 1020.4
Comment remains and is expanded: Sheet a0.2 is showing the storage even though the comment response indicates the storage area would be removed. Please revise drawings.
NEW COMMENT FROM SECOND REVIEW
5. It appears the glazing used in the padel court enclosure would be required to be safety glazing and comply with the requirements of IBC Section 2408. Please amend plans to indicate compliance.



Please contact me if you have any questions about these comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
09/26/2024 Fire New Construction REVIEW COMPLETED
08/29/2024 PDSD Application Completeness REVIEW COMPLETED