Permit Number: TC-COM-0724-01383
Parcel: 141367940

Address:
7401 S WILMOT RD

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0724-01383
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/01/2024 Fire New Construction NOT REQUIRED
08/08/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
08/08/2024 Commercial Building REQUIRES RESUBMIT Permit Review TC-COM-0724-01383 (7401 S WILMOT RD TUCSON, AZ 85756)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).

Structural Plans:
1. The provided structural documents indicate welding is required for assembly of the structure. Welding requires Special Inspection, IBC 110.3.9, 110.3.10, 1705.3.1.
2. Provide a Special Inspection Certificate with Parts A and B completed.
https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf
3. Resubmit when Zoning comments have been resolved.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
08/05/2024 Site Engineering REQUIRES RESUBMIT see zoning comment
07/31/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0724-01383
7401 S WILMOT RD. – PAD-7
Multifamily – Shade Structures (1st Review)

TRANSMITTAL: July 31, 2024

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in PAD-15 zone (UDC 4.7.24). Multifamily is a allowed use in the PAD.

1. The 20’ x 20’ Ramada shown on the plan does not match what is shown on DP22-0298 Sheet 4. Either the building plans need to be revised to match the DP or the DP needs to be revised to match the building plans.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
07/18/2024 PDSD Application Completeness REVIEW COMPLETED