Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0724-01344
Parcel: 140290290

Address:
3301 E GLOBAL LP

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0724-01344
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/07/2024 Site Zoning APPROVED
08/06/2024 Fire New Construction NOT REQUIRED
08/12/2024 Site Engineering NOT REQUIRED
08/12/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/18/2024 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Janet Matz
jmatz@safebuilt.com
Denied
Reason:
Date Completed : 7/18/2024 12:52:46 AM
1. Sheet S1.0 (Partial Room Framing Plan). The structural sheet is missing information that was indicated on the Calculation Keyplan sheet 4 of 9 that was provided with the structural calculations in a separate document by Schneider. The notes that were shown in red include note B1- Reinstall roof beams for bracing west wall and B2: Install new angle bracing to brace south wall. Add these notes to the permit set and include the construction details for the new angle bracing noted on page 5 of 9 of the report.
2. Sheet S1.0 (Partial Room Framing Plan). Clarify how the edge of the existing roof structure is to be treated once the existing roof area above the boilers is removed. It is unclear if the existing roof is to simply be cut off. Clarify if there will be any new partitions, new flashing or roof curbing installed at the edge of the existing roof for drainage.





Building(B) Reviewer
Janet Matz
jmatz@safebuilt.com
Denied
Reason:
Date Completed : 7/18/2024 12:50:59 AM
1. Sheet C1 (Cover Sheet). Indicate that all work will be in compliance with the following codes as adopted by the City of
Tucson.
◦ 2018 International Building Code
◦ 2018 Existing Building Code
◦ 2018 International Energy Code
◦ 2018 International Fuel Gas Code
◦ 2018 International Mechanical Code
◦ 2018 International Plumbing Code
◦ 2017 National Electrical Code
◦ 2018 International Fire Code
2. Sheet C1 (Cover Sheet). Provide a written description of the proposed work on the cover page.
3. Sheet C1 (Cover Sheet). Indicate the occupancy group, the construction type, and the approximate square footage of area of work on the cover sheet. Clarify if the existing structure has an existing fire sprinkler and fire alarm system installed.





Mechanical(M) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Denied
Reason:
Date Completed : 7/13/2024 12:34:58 AM
1. Sheet C1.0 – Missing list of applicable City of Tucson building codes and building code analysis.
2. Sheet C1.0 – Missing description of scope of work of this permit. Include how many SF area is affected in the project work.
3. Sheet S1.0 note 4 reference to see architectural drawings for all roof, floor and wall openings but it’s not submitted.




Plumbing(P) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Denied
Reason:
Date Completed : 7/13/2024 12:34:37 AM
1. Sheet M2.0 general notes 4 calls out piping supports detail in structural plans, but none provide. Provide structural detail supporting the pipes. Details not found in sheet S1.0.
2. Sheet 1/M2.0 notes concrete pad per architectural drawings but this concrete pad detail is missing.
3. 3/M1.0 new mechanical plan shows bended line while sheet M2.0 note states to provide min. 40” straight run of piping without bends or offsets at pump outlet.
07/11/2024 PDSD Application Completeness Express REVIEW COMPLETED