Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0724-01343
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2024 | Commercial Plumbing | APPROVED | |||
| 08/07/2024 | Site Zoning | APPROVED | |||
| 08/16/2024 | Water - PDSD | APPROVED | |||
| 08/12/2024 | Site Engineering | NOT REQUIRED | |||
| 08/16/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/06/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response. 1 Revise the reference to the 2011 NEC to the currently adopted 2017 NEC on the electrical plan notes. 2 Revise the electrical design to comply with the 2017 NEC, including the requirements for Combination type AFCI and GFI protection and Tamper resistant receptacle per NEC art(s) 210 and 406.12.. 3 Indicate branch circuit and panel designation for all branch circuits, devices, including smoke detectors, and feeders associated with the ‘Non- Permitted’ project and correlate with the panel schedule. 4 Provide compliance with the 2018 IECC for lighting. 5 Provide compliance with the 2012 City of Tucson Outdoor Lighting Code for the exterior lighting. 6 Provide egress lighting where applicable per NEC. Ref; 2018 IBC section 107.2.1, 2017 NEC, 2018 IECC, 2012 City of Tucson Outdoor Lighting Code, City of Tucson Commercial Plan Submittal Requirements. |
||
| 08/16/2024 | Commercial Mechanical | REQUIRES RESUBMIT | |||
| 08/16/2024 | Commercial Structural | REQUIRES RESUBMIT | For questions in regards to plan review comments, please contact Bill McClellan by email at bmcclellan@willdan.com or cell (928)580-3179. All applicable comments will be followed by the initials (BM) 1. Sheet A102 Identify new exterior wall bracing to comply with 2018 IRC 602.10. not identified on plans (BM) 2. Sheet A102 Identify required landings at new doors to comply with 2018 IRC R311.3 (BM) 3. Sheet A103 Provide for review, all new headers above new windows and doors to comply with 2018 IRC R602.7(1), incomplete on plans (BM) 4. Sheet A103 Identify wall footing at new exterior end wall at new kitchen. Incomplete 2018 IRC R403.1 & 106.1.1 (BM) 5. Sheet A103 Mechanical system for two new bedrooms needs to be identified on plans for review to per 2018 IRC R303.10 (BM) 6. Sheet A103 Clarify routing of ducting to new kitchen. Ducting is not to replace / occupy space for required insulation. Not clear on plans. 2018 IRC 106.1.1 (BM) 7. Sheet A105 Wall details 3, 4 & 5 do not identify footing depths and widths below grade to comply with 2018 IRC 403. Clarify (BM) 8. Sheet A105 Provide for review the anchor bolt requirement for walls to comply with 2018 R403.1.6. Incomplete (BM) 9. Sheet A105 Provide complete wall framing detail to include blocking and rafter / truss connection to top plate to comply with 2018 IRC table R602.3(1), Incomplete (BM) 10. Sheet A106 New kitchen area, counter outlet spacing needs to comply with 2018 IRC E3901.4 (BM) 11. Sheet A106 New bedroom plan, will need to provide receptacles to comply with 2018 IRC E3901.2 (BM) 12. Sheet A106 New bathrooms will require exhaust fan or window to comply with 2018 IRC R303.3 (BM) 13. Sheet A106 New exterior door require an egress light per 2018 IRC E3903.3 (BM) 14. Sheet A106 Identify on plans required smoke and CO detectors per 2018 IRC R314 & 315 15. Sheet A106 GFCI receptacle for dishwasher will need to be identified as under sink to be accessible under sink 2018 IRC |
||
| 08/08/2024 | Fire New Construction | REQUIRES RESUBMIT | -Specify the type of R4 occupancy. Condition 1 or condition 2. -Include whether or not there is an existing sprinkler system and what type of sprinkler system. 13D or 13R. -Include whether there is a building fire alarm. john.vincent@tucsonaz.gov 5203495581 |
||
| 07/11/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |