Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0724-01343
Parcel: 126100520

Address:
4322 E 6TH ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-0724-01343
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/04/2024 Commercial Mechanical REQUIRES RESUBMIT The 2018 IECC stipulates the mandatory use of mechanical ventilation for residential occupancies. Mechanical ventilation for R-4 occupancies is covered in Section 403.3.2, IMC 2018. Reference: Sections R403.6 and R502.1, IECC 2018. [Initial comment: Show how ventilation is provided for the new bedrooms, bathrooms, and the relocated kitchen. Reference: Section 403.3.2, IMC 2018.]
11/22/2024 Commercial Structural REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.
Below Comment remains and is expanded
Condition 2 requires two Accessible sleeping rooms and bathrooms the plan only shows one Accessible bathroom in the existing portion of the home. The lavatory is within the 5 foot clear floor space of the water closet. This configuration will not allow for a side transfer from a wheel chair. Please revise.
3. Please amend plans to show the sleeping unit with the new wall and bathroom as fully Accessible. Accessible units including their associated facilities (e.g. bathrooms) as required for R-4 Condition 2 occupancies. IBC 1107.6.4.1
http://codes.iccsafe.org/content/icca117-12009comm/chapter-10-dwelling-units-and-sleeping-units#ICCA117.12009_Ch10_Sec1002
• Accessible bathroom technical requirement references 2009 ICC A117.1 - 1002.11.2 Accessible Toilet and Bathing Facility.
• At least one toilet and bathing facility shall comply with Section 603. At least one lavatory, one water closet and either a bathtub or shower within the unit shall comply with Sections 604 through 610. The accessible toilet and bathing fixtures shall be in a single toilet/bathing area, such that travel between fixtures does not require travel through other parts of the unit.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
11/20/2024 PDSD Application Completeness Express REVIEW COMPLETED