Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0724-01300
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/12/2024 | Site Zoning | APPROVED | |||
07/23/2024 | Commercial Mechanical | NOT REQUIRED | |||
07/23/2024 | Commercial Plumbing | NOT REQUIRED | |||
07/23/2024 | Water - PDSD | NOT REQUIRED | |||
07/25/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
07/25/2024 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Please provide an engineering evaluation from an Arizona registered engineer of the existing light poles and the ability for the existing poles to support of new lighting equipment. IBC 107.2 2. Related to above comment; if necessary, Provide for subsequent review process, structural engineering/design/drawings prepared by an Arizona Registrant identifying structural modifications required due to additional imposed equipment loads of the project. IBC 102 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
07/22/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response. 1 Assign a branch circuit or feeder and panel designation for all electrical equipment associated with the project on the electrical site plans that correlate with the panel schedules. 2 Provide electrical power and lighting plans for the Renovated Restroom. 3 Ref; Plan Sheet E-601. 3a. The electrical line diagram shows existing SES rated at 225 amps and the SES schedule shows 400 amps. Please clarify and correlate them on the plans. 3b. There are errors in the wording printed in the electrical line diagram description and plan information above the registrant stamp. Please correct the wording. 4 Per City of Tucson policy, the Outdoor Lighting Special Inspection Certificate will need to be completed including the first Registrant seal and submitted prior to plan review approval. Ref; 2018 IBC section 107.2.1, 2017 NEC, 2012 City of Tucson Outdoor Lighting Code. |
||
07/18/2024 | Fire New Construction | REVIEW COMPLETED | |||
07/03/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
07/23/2024 | Site Engineering | REVIEW COMPLETED |