Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0724-01281
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/05/2024 | Site Engineering | APPROVED | MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01289, TC-COM-0724-01279, TC-COM-0724-01290, TC-COM-0724-01280, TC-COM-0724-01291, TC-COM-0724-01281, TC-COM-0724-01292, TC-COM-0724-01282, TC-COM-0724-01293 | ||
| 08/09/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01289, TC-COM-0724-01279, TC-COM-0724-01290, TC-COM-0724-01280, TC-COM-0724-01291, TC-COM-0724-01281, TC-COM-0724-01292, TC-COM-0724-01282, TC-COM-0724-01293 | ||
| 08/01/2024 | Commercial Electrical | REQUIRES RESUBMIT | MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01289, TC-COM-0724-01279, TC-COM-0724-01290, TC-COM-0724-01280, TC-COM-0724-01291, TC-COM-0724-01281, TC-COM-0724-01292, TC-COM-0724-01282, TC-COM-0724-01293 Permit Review TC-COM (540 W PRINCE RD Unit:UNIT 2-6 TUCSON, AZ 85705) See UNIT 1a comments, permit TC-COM-0624-01263. |
||
| 08/08/2024 | Commercial Mechanical | REQUIRES RESUBMIT | MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01289, TC-COM-0724-01279, TC-COM-0724-01290, TC-COM-0724-01280, TC-COM-0724-01291, TC-COM-0724-01281, TC-COM-0724-01292, TC-COM-0724-01282, TC-COM-0724-01293 1. Provide plans sealed by an Arizona Registrant. Reference: Section 107.1, IBC 2018 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. 2. Provide heating and cooling load calculations for the type B dwelling unit to justify the heating/cooling capacities of the specified HVAC unit. Reference: Section R403, IECC 2018. 3. Clarify details 3/M400 and 7/M400: which is being used? Reference: Section 107.2.1, IBC 2018. 4. Provide guards for equipment located within 10 feet of a roof edge or of a walking surface that is elevated more than 30 inches above the adjoining grade. Reference: Section 304.11, IMC 2018. 5. Correct the calculations demonstrating adequate ventilation for both types of dwelling units (R2, R3, and R4 occupancies, three stories and less) using Section 403.3.2.1, IMC 2018. Note that the minimum continuous and intermittent exhaust airflow rates for kitchens and bathrooms required by Section 403.3.2.3, IMC 2018 are still required. 6. Domestic ductless range hoods may be used for R occupancies provided that mechanical ventilation for the kitchen, required by Section 403.3.1.1, IMC 2018, is otherwise provided. 7. Clarify the location of the exhaust termination for EF-1 with regard to the outside air intakes. Reference: Section 501.3.1, IMC 2018. 8. With respect to keynote 2 on M100, a dryer vent shall be 4” in diameter. Reference: Section 504.8.1, IMC 2018. |
||
| 08/08/2024 | Commercial Plumbing | REQUIRES RESUBMIT | MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01289, TC-COM-0724-01279, TC-COM-0724-01290, TC-COM-0724-01280, TC-COM-0724-01291, TC-COM-0724-01281, TC-COM-0724-01292, TC-COM-0724-01282, TC-COM-0724-01293 1. Provide plans sealed by an Arizona Registrant. Reference: Section 107.1, IBC 2018 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. 2. Hose connection vacuum breakers (Watts 8A, ASSE 1011) are not listed for use where there is continuous pressure (e.g., with an automatic clothes washer). Reference: Sections 303.2 and 608.1, IPC 2018. 3. Specify that all proposed plumbing fixtures shall be listed by a third-party certification agency as complying with the relevant standards. Reference: Section 303.4, IPC 2018. 4. The fixture drain serving an automatic clothes washer shall connect to a fixture branch that is at least 3 inches in diameter. Reference: Section 406.2, IPC 2018 5. Detail 6/P-1.2 calls for the T&P relief to drain to daylight and does not show a drain for the pan. Keynote 1, P-2.2 calls for the T&P to terminate into the pan but does not indicate where the pan drain is to terminate. Coordinate the detail and the keynote. Show the size, route, and termination of both the T&P relief piping and the pan drain. Reference: Section 504, IPC 2018. 6. Provide pressure-absorbing devices for the water connections to appliances equipped with quick-acting or solenoid valves (e.g., clothes washer). Reference: Section 604.9, IPC 2018. 7. Provide a full-open valve for the water supply entrance to each dwelling unit unless each fixture is equipped with stop valves. Reference: Section 606.1(6), IPC 2018. 8. Identify the slope for the proposed 8” private sewer. Reference: Table 704.1, IPC 2018. 9. A separate permit is required for the installation of a private sewer collection system and will require a review of the system design by the Pima County Department of Environmental Quality as well as a building permit from the City of Tucson. Reference Title 18, R18-9-E302, 4.02 General Permit, Arizona Administrative Code. |
||
| 08/09/2024 | Commercial Structural | REQUIRES RESUBMIT | MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01289, TC-COM-0724-01279, TC-COM-0724-01290, TC-COM-0724-01280, TC-COM-0724-01291, TC-COM-0724-01281, TC-COM-0724-01292, TC-COM-0724-01282, TC-COM-0724-01293 ACTIVITY NO. TC-COM-0624-01263 ADDRESS/PARCEL: (540 W PRINCE RD Unit:UNIT 1 TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. As a unified building site & Related to your Accessibility section on sheet G002 and G501, Identify/label which unit is the accessible Type A and Type B unit complying to ICC A117.1 Chapter 11. Per IBC 1107.3 Accessible spaces shall include toilet and bathing rooms, kitchen, living and dining areas and any exterior spaces, including patios, terraces and balconies. 2. On the Site Plan, Identify/Label the accessible route from the Unit Type A to the Amenity Area/Building. 3. Sheet A071, please correct floor plan to show door entry opening where the door is indicated. 4. On the Site Plan, Identify/label the ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE)EV charging stations per ADU 7.4.11 5. Please resubmit. |
||
| 07/30/2024 | Site Zoning | REQUIRES RESUBMIT | MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01289, TC-COM-0724-01279, TC-COM-0724-01290, TC-COM-0724-01280, TC-COM-0724-01291, TC-COM-0724-01281, TC-COM-0724-01292, TC-COM-0724-01282, TC-COM-0724-01293 ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0624-01263. TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01289, TC-COM-0724-01279, TC-COM-0724-01290, TC-COM-0724-01280, TC-COM-0724-01291, TC-COM-0724-01281, TC-COM-0724-01292, TC-COM-0724-01282, TC-COM-0724-01293 540 W PRINCE RD – O-3 Multifamily (1st Review) TRANSMITTAL: July 30, 2024 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the O-3 zone (UDC 4.7.15). Admin Office is a allowed use in the zone (UDC Table 4.8-3). 1. Clarify what the provided Civil and Landscape sheets are for in the plan set as this development was approved under Development Package TD-DEV-0723-00311. As submitted these sheets will not be reviewed in the building permit set and would require a separate submittal. 2. The 12’-6” height shown on the building elevations does not match the height shown on TD-DEV-0723-00311. 3. Clarify why there are 12 permit reviews submitted when there are only 7 buildings shown on the approved DP. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 08/08/2024 | Water - PDSD | REQUIRES RESUBMIT | MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01289, TC-COM-0724-01279, TC-COM-0724-01290, TC-COM-0724-01280, TC-COM-0724-01291, TC-COM-0724-01281, TC-COM-0724-01292, TC-COM-0724-01282, TC-COM-0724-01293 1. Sheet P-2.2 shows a detail (Site Water Main Equipment) with a 1.5” double check valve. Reduced pressure backflow prevention assemblies are required at the water meter for multi-metered properties. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, https://www.tucsonaz.gov/files/sharedassets/public/city-services/tucson-water/water-quality/documents/backflow-ordinance.pdf 2. Show the location of the primary water meter and the backflow prevention assembly on the site plan |
||
| 08/01/2024 | Fire New Construction | REVIEW COMPLETED | MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01289, TC-COM-0724-01279, TC-COM-0724-01290, TC-COM-0724-01280, TC-COM-0724-01291, TC-COM-0724-01281, TC-COM-0724-01292, TC-COM-0724-01282, TC-COM-0724-01293 | ||
| 07/02/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |