Permit Number: TC-COM-0724-01277
Parcel: 106050880

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0724-01277
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/06/2025 Commercial Mechanical APPROVED MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01279, TC-COM-0724-01280, TC-COM-0724-01281, TC-COM-0724-01282, TC-COM-0724-01289, TC-COM-0724-01290, , TC-COM-0724-01291, TC-COM-0724-01292, TC-COM-0724-01293
01/06/2025 Commercial Plumbing APPROVED MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01279, TC-COM-0724-01280, TC-COM-0724-01281, TC-COM-0724-01282, TC-COM-0724-01289, TC-COM-0724-01290, , TC-COM-0724-01291, TC-COM-0724-01292, TC-COM-0724-01293
01/14/2025 Site Zoning APPROVED MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01279, TC-COM-0724-01280, TC-COM-0724-01281, TC-COM-0724-01282, TC-COM-0724-01289, TC-COM-0724-01290, , TC-COM-0724-01291, TC-COM-0724-01292, TC-COM-0724-01293
01/06/2025 Water - PDSD APPROVED MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01279, TC-COM-0724-01280, TC-COM-0724-01281, TC-COM-0724-01282, TC-COM-0724-01289, TC-COM-0724-01290, , TC-COM-0724-01291, TC-COM-0724-01292, TC-COM-0724-01293
01/14/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01279, TC-COM-0724-01280, TC-COM-0724-01281, TC-COM-0724-01282, TC-COM-0724-01289, TC-COM-0724-01290, , TC-COM-0724-01291, TC-COM-0724-01292, TC-COM-0724-01293
01/06/2025 Commercial Electrical REQUIRES RESUBMIT MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01279, TC-COM-0724-01280, TC-COM-0724-01281, TC-COM-0724-01282, TC-COM-0724-01289, TC-COM-0724-01290, , TC-COM-0724-01291, TC-COM-0724-01292, TC-COM-0724-01293
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. The historical records of the City does not have information as to what is present on the grounds of this development. As part of the drawing package, please submit the Outdoor Lighting Code requirement. This is important in that it records what is on the site. 2. Per section 401.2.1 of the City of Tucson/Pima County Outdoor Lighting Code, One hundred percent of the lumens from outdoor light fixtures installed on grade, on poles, and installed on the top or sides of buildings of other structures shall be submitted with your drawings. Please be clear in illustrating this on your drawing by creating a table. 3. Per section 402.1 of the Outdoor Lighting Code, The rated color temperature of light sources (lamps and fixtures) shall not exceed 3500K 4. On the table indicate the type of light, its lumens, its Kelvin rated color temperature, now many of that light type and the total lumens for that light type. 5. At the bottom of that table, indicate/show the total lumens for separately for the shielded and unshielded. 6. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1. In the table, “total” means the sum of shielded and unshielded light. 7. As part of your submittal, indicate the Lighting Area the parcel belongs. 8. Provide your lumens calculation as to the shielded/full cutoff and unshielded allowed for that parcel. (NOTE: Please be mindful of Table 401.1 of the Outdoor Lighting Code is setup. The first row under each type of lighting configuration, indicates the Total (full cut-off plus unshielded. The second row indicates the limit of the unshielded component. Therefore when calculating your lumens allowed subtract the unshielded lumens from the first row in order to calculate the lumens accurately and not double the unshielded lumens allowed.) 9. Please don’t forget to show/locate the different light sources on your site plan. 10. 401.3 All light fixtures that are required to be shielded shall be installed in such a manner that the shielding is effective and permanent. 401.3.1 Light trespass. Light fixtures on the residential side of commercial property adjacent to residential property shall be full cutoff and shall be installed not higher than 10 feet above grade at the property line and no higher than a line rising 20 degrees above the 10 feet until 100 feet from the property line, measured perpendicular to the lot line. 401.3.2 House Side Shields. Outdoor lighting fixtures closer to the lot line than the mounting height of the fixture, measured perpendicular to the lot line, adjacent to residential areas, shall have internal house-side shields. 401.3.3 Fixtures within 25 feet of residential lot lines. Residential and commercial luminaires shall be full cutoff within 25 feet of adjacent residential property lines, measured perpendicular to the lot line. 401.3.4 Flood and spot lamps. Flood or spot lamps shall be aimed no higher than 45 degrees to the horizontal (half-way between straight down and straight to the side) when the source is visible from any adjacent residential property. 11. Please resubmit.
01/06/2025 Commercial Structural REQUIRES RESUBMIT MASTER SET LOCATED AT: TC-COM-0624-01263, WITH REVIEWS TO BE PERFORMED ON: TC-COM-0724-01277, TC-COM-0724-01278, TC-COM-0724-01279, TC-COM-0724-01280, TC-COM-0724-01281, TC-COM-0724-01282, TC-COM-0724-01289, TC-COM-0724-01290, , TC-COM-0724-01291, TC-COM-0724-01292, TC-COM-0724-01293
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. SHEET A071: At least one bedroom and one bathroom has to have 31-3/4” doorway clear opening per ICC A117.1 1104.5.2 (the floor plan shows 29-5/8”). Please make the necessary correction for EACH UNIT. 2. Locate and Identify the structural blocking within walls in the bathrooms where future grab bars will be installed. 3. Please resubmit.
12/20/2024 PDSD Application Completeness Express REVIEW COMPLETED