Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2
Permit Number - TC-COM-0723-01870
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/10/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/10/2023 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Comment not addressed. [Initial comment: Replacement of AC units for the apartment will require a heating/cooling load calculation to justify the capacities of the units being installed (Sections R403.7, IECC 2018). The units themselves will also have to comply with Sections R403.1 and R503.1.2, IECC 2018 for efficiency and controls. Provide specifications for the replacement equipment.] 2. Comment not addressed. [Initial comment: Note: New heating /cooling loads are not required for emergency replacement of cooling and heating equipment where there are no alterations, additions, or changes of occupancy, the equipment does not increase in capacity, and the existing equipment was installed prior to January 1, 2013.] |
||
08/08/2023 | PDSD Application Completeness | REVIEW COMPLETED |