Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0723-01864
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/25/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
09/25/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 9/19/2023 10:00:14 AM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 9/19/2023 10:55:25 AM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 9/20/2023 9:28:39 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Conditionally Approved Reason: Date Completed : 8/10/2023 5:43:28 PM Electrical Review of Chuze Fitness By: Ron Ross PE Electrical approved with the following comments to correct or revise for construction set. E001 ELECTRICAL SITE PLAN: Not included in set, but E110 sheet seemed sufficient. E110 ELECTRICAL LIGHTING FLOOR PLAN: Could not locate Keynotes 2, 6, and 12. E120 ELECTRICAL ROOF POWER PLAN: Could not locate Keynote 3. E401 ENLARGED ELECTRICAL PLANS: Could not locate Keynotes 10, 11, 15, 17, 21, and 22. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 9/23/2023 5:41:28 PM Second Plumbing Review: OK 1). Resolved-Plan page P601 water heater schedule list a EWH-1 point of use EEmax water heater, there is not a EWH-1 shown on the water piping plan P401, and this doesn't correlate with the existing 1" hot water system shown supplying the hot piping in the remodeled areas. See P111 & P401. plan pages need to correlate -IPC 106.3.1 2). Resolved- on P601 need ASSE 1070 mixing valves - IPC 419.5 3). Resolved-P602 trap primer detail needs a shut off valve - IPC 606.2 |
||
09/18/2023 | PDSD Application Completeness | REVIEW COMPLETED |