Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0723-01853
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/01/2023 | Site Zoning | APPROVED | |||
08/31/2023 | Water - PDSD | APPROVED | |||
08/01/2023 | Site Engineering | NOT REQUIRED | |||
08/31/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/11/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 8/11/2023 12:20:44 PM Pending building revisions. No structural revisions needed at this time. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 8/11/2023 12:18:11 PM 1) Sheet G01.02: Clarify the table showing the renovation area is 2259 GSF and the total area is only 1819 GSF. 2) Sheet G01.02: Include the list of deferred submittals. 3) Sheet G02.01: Incorrect occupant load. The break room and waiting area are areas of assembly for determining the occupant load per Table 1004.5 (example: areas of tables and chairs = 1 per 15 sf, chairs only = 1 per 7 sf). The office gross area includes the corridors and closets (see definition of "Floor Area, Gross"). Please revise all applicable sheets. Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 8/11/2023 12:19:49 PM Pending building revisions. No mechanical revisions needed at this time. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 8/11/2023 12:19:13 PM Pending building revisions. No electrical revisions needed at this time. Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 8/11/2023 12:20:20 PM Pending building revisions. No plumbing revisions needed at this time. |
||
08/13/2023 | Fire New Construction | REQUIRES RESUBMIT | -Indicate fire sprinklers and fire alarm will be deferred submittals. john.vincent@tucsonaz.gov 5203495581 |
||
07/31/2023 | PDSD Application Completeness | REVIEW COMPLETED |