Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0723-01789
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/11/2023 | Site Zoning | APPROVED | |||
| 10/16/2023 | Water - PDSD | NOT REQUIRED | |||
| 10/16/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/25/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/21/2023 6:36:28 PM See the building review comments. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/21/2023 6:34:12 PM 1) Sheet A-1 (Proposed Floor Plans): Show details for dwelling unit fire-rated separation walls per 2018 IBC Section 420.2. Note #3 states that the unit demising wall (between units A and C) is being insulated which would require the removal of the drywall. If the wall surface is being removed, the required fire-rated separation assembly will need to be installed when replacing the drywall. 2) Sheet A-3 (Electrical Drawings): The panel schedule for subpanel A does not show a minimum of two kitchen counter small appliance circuits. (2017 NEC sections 210.11(C)(1) and 210.52(B)(1)) 3) Sheet A-3 (Electrical Drawings - Riser Diagram): Show the equipment grounds are being ran with the feeders from the main disconnects to the subpanels. All service grounding and bonding are to be done only at the main service equipment and the neutrals and grounds are to be separated at the subpanels. (2017 NEC section 250.24(A) and (B)) 4) Sheet A-3 (Electrical Drawings - Riser Diagram): Service riser conductors shown as 4/0 aluminum are too small for 300 amps. (2017 NEC Table 310.15(B)(16)) 5) Sheet A-3 (Electrical Drawings): Missing a receptacle on the closet wall space between the closet door and the bedroom entrance door in Unit C. (2017 NEC section 210.52) Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/21/2023 6:35:53 PM See the building review comments. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/21/2023 6:35:01 PM See the building review comments Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/21/2023 6:36:12 PM See the building review comments. |
||
| 09/14/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |