Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2

Permit Number - TC-COM-0723-01729
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/24/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
07/24/2023 Commercial Plumbing REQUIRES RESUBMIT Provide additional information regarding the scope of work. Provide a single line diagram that shows the location of the gas meter(s), from the meter...what is the diameter of the gas line and the length, should it branches into multiple lines for multiple dwellings...provide that gas line diameter and the length all the way where the gas diameter changes. Provide the location of the appliances along the gas line and provide the gas demand (BTU) for each appliance(s). Finally provide the effective length of that entire line of gas pipes (this is from the gas meter to the farthest appliance).
NOTE: If your have multiple gas meters, you will be submitting multiple single line diagrams. Please make sure that you label these diagrams using the unit numbers.
NOTE: 199,000 BTU is the Navien NPE 240A2's gas demand per their website information.
NOTE: 65,000 is the average BTU for cooking range (please verify the actual BTU from the actual range info).

Please re-submit
07/20/2023 PDSD Application Completeness REVIEW COMPLETED It appears the site plan uploaded lists multiple buildings/units. Each individual building/unit requires its own permit. This permit is for (2440 E GLENN ST Unit:BLDG 1 UNIT 1102) only, please start new permits for the other buildings/units.