Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0723-01644
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/11/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/11/2023 | Commercial Structural | REQUIRES RESUBMIT | Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. See Site Zoning Comment, wall over 6 ft, setback requirement will have to be addressed. 2. Proposed wall is 8 ft, structural calculation and structural drawings will have to be done by an Arizona Licensed Registrant, drawings/calculation to be sealed/signed/dated. 3. Submit Electrical drawing for the automatic sliding gate as well as the receptacles & sconces shown on the plan drawing. Submit an image of the sconces making sure to show full cutoff, the lumens, light source temperature and lumen calculation complying to the Outdoor Lighting Code. 4. Provide detail drawings for the metal fence/gate including the concrete apron. 5. Please resubmit. |
||
| 07/18/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
| 07/13/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-COM-0723-01644 3121 E KLEINDALE RD Zoning C-1 TRANSMITTAL DATE:July 13, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans and is submitted at: https://tdc-online.tucsonaz.gov/#/home. The DP will need to be approved prior to approval of this building permit. 2. Per UDC Section 6.6.2.I: The maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard .) Based on a proposed wall height of 8’-0” a Design Development Option (DDO) will need to be processed and approved to increase the height of a wall. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf If you have questions about the DDO application or process please contact Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington georgia.pennington@tucsonaz.gov If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 07/16/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 07/07/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |