Permit Number: TC-COM-0626-00997
Parcel: 12108001B

Address:
1101 N WILMOT RD

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0626-00997
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/22/2026 Commercial Building Standard APPROVED
07/17/2026 Commercial Electrical Standard APPROVED
07/22/2026 Site Engineering Standard APPROVED
07/21/2026 Commercial Mechanical Standard NOT REQUIRED
07/21/2026 Commercial Plumbing Standard NOT REQUIRED
07/23/2026 Site Zoning Standard NOT REQUIRED
07/21/2026 Water - PDSD Standard NOT REQUIRED
07/23/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/17/2026 Outdoor Lighting Standard REQUIRES RESUBMIT Outdoor Lighting Review TC-COM-0626-00997 (1101 N WILMOT RD TUCSON, AZ 85712)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. The replacement, relocation and installation of new lighting fixtures requires compliance with the City of Tucson Outdoor Lighting Code.
2. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 104.2.1, 401.2. Include all exterior fixtures on the property in the calculations. List shielded and unshielded lights in the calculation.
3. Full cutoff lighting fixtures under a canopy or overhang are exempt from the lumen calculations requirement, OLC 401.2.1(3). Clearly show or indicate that the new lighting fixtures are full-cutoff and under an overhang.
4. Show lamps with a maximum of 3500K color temperature, OLC 402.1.

5. Specify any exceptions used.

6. Provide Curfew lighting controls If applicable Per section 403.
07/22/2026 Fire New Construction Standard REVIEW COMPLETED
07/01/2026 PDSD Application Completeness Express REVIEW COMPLETED