Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0626-00995
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/29/2026 | Historic | NOT REQUIRED | Change from restaurant to bar with no exterior changes being proposed will not trigger any historic review. However, any exterior modifications to meet the new use will trigger historic review If you have any questions, contact Michael.Taku@tucsonaz.gov |
||
| 07/10/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 08/07/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/27/2026 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. The submitted construction drawings were for Permit # T17CM02892 , under the 2012 I-codes and the registrant’s seal is dated 8/8/2017 and is no longer valid and cannot be used for this Request for Change of Use from Food Service (restaurant) to Alcoholic Beverage Service use (bar) IBC 107.2.1 Please submit a new set of construction drawings for this project. 2. Please provide the following information for this A-2 conversion from restaurant to bar. IBC 107.2.1 A. A code analysis identifying the proposed use as a change of occupancy under the IEBC. B. Existing and proposed occupant load calculations. C. A life safety plan demonstrating compliance with the current IBC for: D. Means of egress. E. Plumbing fixture counts. F. Accessibility. G. Fire protection systems. H. Structural verification where occupant loads or live loads increase. Although both occupancies are Group A-2, the conversion from a restaurant to a bar often results in a substantially higher occupant load and different life-safety requirements. This is one of the more significant "same-group" occupancy changes because the code implications can be extensive despite the occupancy classification remaining A-2. 3. Please submit construction drawings designed to the applicable, currently adopted codes IBC 107.2.1 2024 International Building Code (IBC) 2024 International Existing Building Code (IEBC) 2017 ICC A117.1 Accessibility Code (by reference) 2024 International Mechanical Code (IMC) 2024 International Plumbing Code (IPC) 2023 National Electrical Code (NEC) 2024 International Fire Code (IFC) 2024 International Fuel Gas (IFGC) 2018 International Energy Conservation Code (IECC) City of Tucson/Pima County Outdoor Lighting Code Local Amendments to Above Codes ( www.tucsonaz.gov/pdsd/building-codes ) 4. Please provide a copy of the construction contract or detailed estimates to verify the project valuation. If additional information is not provided, the permit fees will be assessed based on the calculated valuation in accordance with IBC 109.3 and the adopted fee schedule. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 07/22/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0626-00995 (874 E UNIVERSITY BL TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide updated electrical plans showing the complete scope of work related to changing from a restaurant to a bar. |
||
| 07/27/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | Provide updated mechanical plans showing the complete scope of work related to changing from a restaurant to a bar. If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 07/27/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Provide updated plumbing plans showing the complete scope of work related to changing from a restaurant to a bar. If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 08/07/2026 | Design Review Standard | REQUIRES RESUBMIT | Applicant has indicated the Main Gate District Urban Overlay Zone (MGD) will be pursued. Please submit a complete Design Package following these instructions: https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf. If you have any questions, please let me know: maria.gayosso@tucsonaz.gov. Thank you. | ||
| 07/27/2026 | Fire New Construction Standard | REQUIRES RESUBMIT | Please provide an updated and full set of drawings for a proper review. john.vincent@tucsonaz.gov 5203495581 |
||
| 07/29/2026 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: Olga Salazar PDSD Zoning Review Section PROJECT: TC-COM-0626-00995– Bar Tenant Improvement (1st Review) 874 East University Boulevard TRANSMITTAL DATE: July 29, 2026 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. COMMENT: The underlying zoning is C-1 which does not permit Commercial – Alcoholic Beverage Services. The site is in the Urban Overlay District – Main Gate District which allows Alcoholic Beverage Services (Main Gate District Section C-2, sheet 9. The site is also within a Historic Preservation Zone. To allow the proposed use an approved application from Special Districts and Historic review are required. Please note, Zoning approval is contingent upon these approvals. 2. COMMENT: On cover sheet, correct the following information under code analysis: - Correct existing zoning from “HC-1” to “UHC-1” - Specify both the existing zoning use “Food Service, Accessory Use: Alcoholic Beverages Service” and the proposed use “Alcoholic Beverage Services” - Per Pima County Assessor’s Record Map (available at: https://www.asr.pima.gov/ParcelData/Map/Arm/MP01/01004_01.pdf) the total area of Pima County Parcel Number 124-05-050A is 8,880 sq.ft. Please update this information. 3. COMMENT: On cover sheet, under scope of work, provide a description of the current request for a change of use. 4. COMMENT: More comments may be forthcoming based on the next submittal's response. If you have any questions about this transmittal, contact Olga Salazar at Olga.Salazar@tucsonaz.gov. |
||