Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0626-00989
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/15/2026 | Commercial Building | APPROVED | |||
| 07/15/2026 | Commercial Mechanical | APPROVED | |||
| 07/15/2026 | Commercial Plumbing | APPROVED | |||
| 07/13/2026 | Site Zoning | APPROVED | |||
| 07/15/2026 | Water - PDSD | APPROVED | |||
| 07/10/2026 | Site Engineering | NOT REQUIRED | |||
| 07/15/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/15/2026 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0626-00989 (2553 N CAMPBELL AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Update 'Kitchen General Note', Sheet E2.1, to include GFCI protection for all appliance OUTLETS per NEC 210.8(D). Readily accessible per NEC 210.8. 2. Update the code reference on 'Kitchen General Note', Sheet E2.1, to correctly reference NEC 210.8(B)(2) & 210.8(B)(3). Readily accessible per NEC 210.8. 3. Readily accessible may require GFCI CB or upstream protection or other approved means. 4. Reference Sheet E3.2, Panel Schedule 'C'. Multiple circuits are missing the (*, **, ***) designations. Please update to include this on all loaded circuits. (excluding 'Spare' or 'Bussed Space'). |
||
| 07/15/2026 | Outdoor Lighting | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-0626-00989 (2553 N CAMPBELL AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Show lighting fixture EMR as Full-Cutoff, per Chapter 2 definition of the OLC. Show color Maximum Color Temperature of 3500K, OLC 402.1. |
||
| 07/15/2026 | Fire New Construction | REVIEW COMPLETED | |||
| 07/01/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |