Permit Number: TC-COM-0626-00972
Parcel: 12112404E

Review Status: Requires Resubmit

Review Details: HAST - COMMERCIAL NEW ADD/ALT FAST TRACK v.3

Permit Number - TC-COM-0626-00972
Review Name: HAST - COMMERCIAL NEW ADD/ALT FAST TRACK v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/20/2026 Commercial Building APPROVED
11/20/2026 Commercial Mechanical APPROVED
11/20/2026 Commercial Plumbing APPROVED
11/12/2026 Outdoor Lighting APPROVED
11/13/2026 Site Engineering APPROVED
11/20/2026 Water - PDSD APPROVED
11/20/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/17/2026 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0626-00972 (1635 N CRAYCROFT RD TUCSON, AZ 85712)
TC-COM-0726-01109
TC-COM-0726-01110
TC-COM-0726-01111
TC-COM-0726-01112
TC-COM-0726-01113
TC-COM-0726-01114
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Reference sheet EP402, Duplex 1 power plan. Plans show the bathroom circuit 1B-13 in the bathroom receptacle AND at the Smoke Alarms for BOTH units. Circuit 1B-13 cannot be used outside the bathroom, and cannot cross into the other unit.
a. Bathroom requires dedicated circuit and cannot be used on the smoke detectors.
b. Provide a separate circuit for the smoke alarms.
2. Reference Sheet EP402, Duplex 1, Dryer circuit in the outdoor closet. Circuit 1B-26/28 is shown in both units. Update and correct.
3. Reference Sheet EP402: Provide GFCI protection for all kitchen receptacles, including the Range and receptacle shown above the range. NEC 210.8(A)(6) & 210.8(D)(8).
4. Reference Sheet EP402: Provide GFCI protection for the Dryer receptacle outlet per NEC 210.8(D)(11).
11/18/2026 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Jeffrey W. Cassidy, Planner I
Planning & Development Services Department – Current Zoning Review Section, Commercial

PROJECT:
TC-COM-0626-00972 – Commercial – New resident clubhouse building at existing apartment complex
1635 N CRAYCROFT RD TUCSON, AZ 85712 (R-2 Zoning)
Commercial Building Plan Review – 2nd Review

TRANSMITTAL DATE:
November 18, 2026

1. COMMENT: Zoning has completed its review of the submitted building plan set and cross-referenced it against the associated Development Package. However, final approval of Commercial Permit TC-COM-0626-00972 cannot be granted until the Development Package TD-DEV-0726-00190 has received full approval and has been issued. Per UDC §3.3.3.G, building permits for sites requiring a Development Package may not be issued prior to DP approval, as the building plans must be consistent with an approved site plan. Please resubmit for final approval once the Development Package has been approved and issued by all applicable reviewers. For final approval, ensure the building plans match the approved DP regarding footprint, proposed height, and square footage, and that the downspout and structure drainage systems shown in the building plans are consistent with those depicted in the Development Package plan set.

2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

3. COMMENT: Corrected commercial building permit (per any updates to TD-DEV-0726-00190.

4. COMMENT: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home .

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .
11/19/2026 Fire New Construction REVIEW COMPLETED
11/12/2026 PDSD Application Completeness Express REVIEW COMPLETED